background image

   
 
 

INSTALLATION  –  OPERATION  - 
MAINTENANCE USER MANUAL 

WALL MOUNTED EXPROOF AXIAL FANS 
 

                           

 

VENCO Havalandırma ve Makina San.ve Tic. A.Ş. 

2004. Cad. No:5 45400 OSB Turgutlu – MANİSA / TÜRKİYE 

Tel: 0090 (236) 332 5070     Fax: 0090 (236) 332 5030 

www.venco.com.tr   [email protected] 

 

2019.10 

2019.02 

Summary of Contents for VD-EX

Page 1: ...CE USER MANUAL WALL MOUNTED EXPROOF AXIAL FANS VENCO Havaland rma ve Makina San ve Tic A 2004 Cad No 5 45400 OSB Turgutlu MAN SA T RK YE Tel 0090 236 332 5070 Fax 0090 236 332 5030 www venco com tr ve...

Page 2: ...d keep it Do not use devices as a workbench or a storage area VENCO VD EX Wall Mounted Axial Type Exproof Fans can only be operated in conditions of intended design and technical specifications DEVICE...

Page 3: ...assified as a place in which an explosive atmosphere consisting of a mixture with air or flammable substances in the form of gas vapour or mist is likely to occur in normal operation occasionally Zone...

Page 4: ...y whether the fan wheel runs freely Before installation check the minimum air gap between the blade tip and the housing according to the following table The fan can be mounted parallel to the wall wit...

Page 5: ...2019 10 4 8 Sample pictures of the assembled device Fan Diameter VD EX Min mm Max mm 315 0 6 1 6 355 0 8 1 8 400 1 2 450 1 25 2 25 500 1 4 2 4 560 1 4 2 4 630 1 58 2 58 710 2 6 3 6...

Page 6: ...fan has direct contact with the outside air a plastic damper must be used on the outer side of the outer wall to stop this contact for lightning protection ALL ELECTRICAL CONNECTIONS SHALL BE DONE ACC...

Page 7: ...ar position after rotation When dismantling the crate to gain access to the fan assembly care should be taken to avoid injury from sharp edges nails staples splinters etc 8 MAINTENANCE Periodically ch...

Page 8: ...full load current specified on the motor nameplate Rotate the motor shaft by hand Investigate any sound of grinding noises internal chaffing rubbing or stiffness Any observed defect may indicate that...

Page 9: ...2019 10 8 8 ANNEX 11 1 Annex 1 Electrical Wiring Diagrams Motor connection without termic Motor connection with termic...