10
Configuring and setting
CONFIGURING AND SETTING YOUR CLOCK
Apply 9-12VAC.
The clock will display '50' or '60' for 3s, depending on the AC power
frequency (Hz) in your area. This indicates that the zero cross detection part
of the clock circuit is working fine.
(If the clock displays '00', you either applied a DC voltage instead of an AC
voltage, or there is a problem with the zero cross detection circuit T1, R1, R2,
R6, C3, D5)
DC applied or zero cross error
DC applied or zero cross error
DC applied or zero cross error
50Hz AC: OK
50Hz AC: OK
50Hz AC: OK
Next, the clock will show the display mode for 3s
Press the button briefly to toggle between 12h and 24h display mode.
WARNING: This is a high voltage device !
Do not touch anything else than the plastic part of the pushbutton while
the clock is plugged in
.
The display mode is stored in eeprom and will be remembered at next power
on.
24h system selected
24h system selected
24h system selected
12h system
12h system
12h system selected
selected
selected