background image

MULTIFUNCTION RELAY SWITCH 

K8015

 

ILLUSTRATED ASSEMBLY MANUAL 

 

H8015IP-2 

Total solder points: 85 
Difficulty level: 

beginner

 1

  2

  3

   4

 5 

advanced

 

14 Diffe

rent fun

ctions in

cluding

 

timers, 

switchin

g, flash

ing, inte

rval, 

random

 switchi

ng, .... 

Summary of Contents for K8015

Page 1: ...ION RELAY SWITCH K8015 ILLUSTRATED ASSEMBLY MANUAL H8015IP 2 Total solder points 85 Difficulty level beginner 1 2 3 4 5 advanced 14 Different functions including timers switching flashing interval random switching ...

Page 2: ...for delays of 2s up to 12 days EEPROM for delay time storage in case of power failure On board transient filter for the relay contacts Suitable for control of incandescent lighting halogen lighting fluorescent lighting fans valves buzzers Specifications Operating voltages 9 12 VAC or 12 VDC Max load 2 5A 550W 220V 275W 110V Dimensions pcb wxdxh 65 x 57 x 25mm ...

Page 3: ...the eyes Needle nose pliers for bending leads or to hold components in place Small blade and Phillips screwdrivers A basic range is fine For some projects a basic multi meter is required or might be handy 1 2 Assembly Hints Make sure the skill level matches your experience to avoid disappointments Follow the instructions carefully Read and understand the entire step before you perform each operati...

Page 4: ...ints are cone shaped and shiny 3 Trim excess leads as close as possible to the solder joint REMOVE THEM FROM THE TAPE ONE AT A TIME AXIAL COMPONENTS ARE TAPED IN THE CORRECT MOUNTING SEQUENCE You will find the colour code for the resistances and the LEDs in the HALG general manual and on our website http www velleman be common service aspx ...

Page 5: ...104 8 Capacitors IC1 8p 7 IC socket Watch the position of the notch D1 1N4148 1 Diode Watch the polarity D CATHODE ZD1 5V1 500mW 2 Zener diode Watch the polarity ZD CATHODE R9 220 2 2 1 B 9 R10 220 2 2 1 B 9 5 1 2W Resistors R D2 1N4007 D3 1N4007 D4 1N4007 D5 1N4007 3 Diodes Watch the polarity D CATHODE SW1 KRS0611 6 Push button SW2 DS 4 9 Dip Switch Watch the orientation 1 ...

Page 6: ...4 Electrolytic Capacitors Watch the polarity C RY1 VR10V121C or eq 17 Relay RY Construction LD CATHODE LD1 3mm RED 10 LED Watch the polarity SK1 12 Pin header C5 100nF 250V 15 Capacitors VDR1 VDR 300 VAC VDR2 VDR 300 VAC 16 VDR IC1 VK8008 Programmed PIC12CE518 18 IC Watch the position of the notch ...

Page 7: ...nsient suppressor to reduce contact wear With very small loads it might be necessary to omit the shunt Transient suppressor over the normal open contact Transient suppressor over the normal closed contact 19 Shunt for transient suppressor S K 1 SK1 ...

Page 8: ...d time elapses Applications General timing Hint use as Toggle mode with a very long delay time This will ensure lights will not remain on forever if forgotten to turn them off Staircase timer Push to turn on After pre set time has elapsed load will turn off A push during on time will restart timer and stretch on time Applications staircases basements storage rooms front door light ing Dual time st...

Page 9: ...annot be turned on again before delay2 elapses Continuous pushing will not switch on the load when delay2 elapses Applications Prohibit continuous operation of heating airco TV spa Turn off delay Push to turn on load When button is released timer is started When time elapses load is turned off Repeated push during on time restarts timer Applications Allow a pump or fan to remain on for a while aft...

Page 10: ...button is released At release the timer is started When time elapses output is turned off Pushing again during on time will restart the timer at release of the button Applications Ventilation of restrooms restroom flush control Interruptible Real Time staircase timer Press briefly to activate interval 1 a prolonged push will activate interval 2 The charge will be neutralised after the interval eve...

Page 11: ...ired time has elapsed Push the button again to stop recording The load is turned off and the recording stops The load will blink once To confirm the recorded time press the button briefly within 5 seconds after stopping the recording The load will blink once to confirm the recorded time Then you can store delay2 Push the button once The load blinks twice and turns on The recording starts Wait unti...

Page 12: ...12 Connection example Low Voltage 22 Connection example Low Voltage 12V 2 5A max ...

Page 13: ...13 Connection example Mains Voltage 23 Connection example Mains Voltage 12DC or 9VAC 300mA 500W 230V max 275W 110V max 2 5A max ...

Page 14: ...14 PCB 24 PCB P8015 2 VELLEMAN 12V IN PUSHBUTTON COM NO NC NO NC VDR2 VDR1 ZD1 T2 T1 SW2 SW1 SK4 SK3 SK2 1 SK1 RY1 R10 R9 R8 R7 R6 R5 R4 R3 R2 R1 LD1 IC1 D4 D5 D3 D2 D1 C5 C4 C3 C2 C1 NC NO COM C2 C1 ...

Page 15: ... 7 GP1 6 GP2 T0CKI 5 VSS 8 GP5 OSC1 CLKIN 2 VDD 1 IC1 PIC12CE518 R5 10K T1 BC547 R6 10K SW2 DS 4 RY1 VR10V121C LD1 LED3RL D1 1N4148 R4 10K R9 220 0 6W R10 220 0 6W SK1 JP3 C5 100nF 250V SK4 SCREWL03 R2 1K5 SK2 SCREW02 T2 BC547 R7 1K R3 1K5 C2 100n SK3 SCREW02 SW1 KRS0611 COM NO NC PUSH BUTTON 12V IN R8 10K VDR1 VDR300 VDR2 VDR300 ...

Page 16: ...ons and typographical errors reserved Velleman Components nv H8015IP 2004 ED2 rev 1 0 VELLEMAN Components NV Legen Heirweg 33 9890 Gavere Belgium Europe www velleman be www velleman kit com 5 4 1 0 3 2 9 2 9 1 1 4 3 ...