Put SW2 in the 6V position. Measure the voltage across the output termi-
nals. Output voltage should be 6.8V +/- 0.2V
N
-
AC
ON
L
AC POWER
AC
Vdc
K8012
ACCU
+
14.7V=
12V
>4Ah
33
Ω
Put SW2 in the 12V position, put SW1 in the >4Ah position. Connect the
supplied 33
Ω
/5W resistor to the output terminals. Measure the voltage
across the resistor. It should read 14.7V +/- 0.2V
N
-
AC
ON
L
AC POWER
AC
Vdc
K8012
ACCU
+
7.3V=
6V
>4Ah
Ω
33
Put SW2 in the 6V position, put SW1 in the >4Ah position. Connect the
supplied 33
Ω
/5W resistor to the output terminals. Measure the voltage
across the resistor. It should read 7.3V +/- 0.2V
N
-
AC
ON
L
AC POWER
AC
Adc
K8012
ACCU
+
1A=
10A
12V
>4Ah
Ω
8.2
Put SW2 in the 12V position, put SW1 in the >4Ah position. Connect the
supplied 8.2
Ω
resistor in series with the multi-meter. Switch the multi-meter
to the ‘10A DC’ -position. It should read 1A +/- 0.1A.