Summary of Contents for PCG10

Page 1: ...PC Generator PCG10 K8016 CHECK THE Pc Lab2000T M GETTING STARTED GUIDE FOR SOFTWARE INSTALLATION R Re ef fe er re en nc ce e M Ma an nu ua al l...

Page 2: ...PCG10 K8016 2 VELLEMAN Instruments is a division of VELLEMAN Components NV Legen Heirweg 33 9890 Gavere Belgium Support updates http www Velleman be Velleman Instruments HPCG10_GB 2001 1...

Page 3: ...g antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an e...

Page 4: ...PT1 2 or 3 Specifications Power supply Standard 12V DC adapter 800mA PS1208 Direct Digital wave synthesis DDS 32K wave table Frequency setting resolution 0 01 Amplitude range 100mVpp to 10Vpp 600 Ohm...

Page 5: ...making measurements and for safety reasons it is important to know some information about the measured unit Safe devices are Battery operated equipment Equipment supplied via a transformer or adapter...

Page 6: ...put ready LED indicates if output signal is present 4 Power indication LED software driven 5 Adapter connection observe the polarity 6 Parallel port connector to computer 7 Parallel pass through conne...

Page 7: ...ltage DC adapter to the unit 12VDC 800mA pin positive MATTENTION Only use adapter with correct voltage otherwise the unit could be damaged Using a wrong power supply could blow the internal fuse The f...

Page 8: ...king the More Funct button and then the LIB button A set of library waveform files are included on the disk Waveforms of 32000 data points File name Description BURST1 LIB Sine burst 1 cycle BURST2 LI...

Page 9: ...e sweep ranges are indicated on the buttons The sweep repetition rate is proportional to the sweep frequency range selected Sync output supplies a high going pulse at the start of each sweep This puls...

Page 10: ...ing and creating the waveform library file Library files Waveform library files are normal text files Files can be created and edited with standard text editors such as Notepad or Wordpad or with a sp...

Page 11: ...h comma and dot are interpreted as decimal separators Writing the waveform file The data points in the waveform file make up one function generator output cycle There must be at least two data points...

Page 12: ...data points are equally distributed over the wave period If you like to increase the distance between two data points you can type the distance in parenthesis on separate line between the data values...

Page 13: ...b The contents of the file 1 0 1 0 Triangle wave with skew File name tri_skw lib The contents of the file 1 0 30 1 0 10 1 0 Triangle wave File name tri1 lib The contents of the file 1 0 1 0 1 0 Trapez...

Page 14: ...e contents of the file 1 0 10 10 1 0 Stairs File name stairs1 lib The contents of the file 1 0 1 0 0 0 5 0 0 0 0 0 5 0 1 0 Pulses of different amplitude File name pulses1 lib The contents of the file...

Page 15: ...59 0 31 0 00 0 31 0 59 0 81 0 95 1 00 0 95 0 81 0 59 0 31 0 00 Sine burst File name burst01 lib The contents of the file 0 00 21 0 31 0 59 0 81 0 95 1 00 0 95 0 81 0 59 0 31 0 00 0 31 0 59 0 81 0 95...

Page 16: ...a 5 level adjustment to the output voltage and 120mV adjustment to the offset voltage when the square wave output mode is selected Tools menu Wave Editor Opens the waveform data editor Bode Plotter S...

Page 17: ...on and adjust the Y position until the trace is in the middle of the screen Make following selections on the Bode Plotter interface Select proper Frequency Range Select proper Frequency Start Click th...

Page 18: ...rement from DC 0Hz Frequency stepping There are two alternative stepping modes logarithmic and linear If the checkbox Log Freq Steps is checked the frequency step is at the first decade equal to the s...

Page 19: ...following operations before the start of the measurements Turn the oscilloscope s input switch to AC position Adjust the scope s trace to the middle of the screen Note When oscilloscope s input switc...

Page 20: ...colors when Multiple Trace Mode is selected View Menu Markers Marker function for absolute and relative voltage measurement is provided The absolute voltage level in dBV or the voltage difference in d...

Page 21: ...LPT Check the printer port setting in the BIOS SETUP of the computer Select standard parallel port mode SPP also named compatible mode or Centronics mode No output signal Ready LED on the front panel...

Page 22: ...e invoice VELLEMAN Components limits its responsibility to the reparation of defects or as VELLEMAN Components deems necessary to the replacement or reparation of defective components Costs and risks...