Programming & operation
NOTE
: For reference, the VelbusLink configuration screen for the VMBKP contains a “programming code generator”
section. This useful tool will present you with the codes you need to enter on the keypad.
It does not send the codes to
the keypad however, these need to be manually entered using the physical buttons on the keypad.
Power-up the keypad
The keypad has a power-up delay of 1 minute after power has been applied. This is the time frame designed for setting
the keypad to programming mode with the DAP (Direct Access to Programming) code. See “DAP CODE –
2 8 2 8” below
for more information.
1.
The keypad emits continuous beeps for 1 minute after power-up, and the amber LED is flashing.
2.
The power-up delay can be stopped instantly with 1 2 # if the delay beep is found annoying and setting the
keypad to programming mode with the DAP code is not required.
3.
The keypad will automatically set itself to Normal Operation Mode after the 1 minute power-up delay has
expired or has been stopped with 1 2 #.
Set the keypad in programming mode using the Master Code
In order to program the keypad, it needs to be set in programming mode first.
When the keypad is in normal operation after the power-up delay, it can be set in programming mode by entering the
Master Code and validating it with * *.
Master code
Validation
0 0 0 0
* *
For the owner’s convenience in programming the first time, a Master Code 0 0 0 0 has been stored in the keypad upon
leaving the factory. This is NOT a default code. For security reasons, the owner should as soon as possible replace this
Master Code with a personal one. See “
18 for more information.
The Center LED (amber) is ON after the keypad confirms programming mode with 2 beeps.
DO NOT power off the keypad while it is in p
rogramming mode. Otherwise, the data in the keypad’s memory may
become corrupted.
Direct Access to Programming mode with “DAP” code
-- 2 8 2 8
In case the Master Code is forgotten, apply the following procedure to set the keypad into programming mode with the
DAP code:
1.
Switch OFF the power for 1 minute to ensure that the keypad is fully discharged.
2.
Switch ON power again. The keypad is in Power-up Mode for 1 minute. The buzzer emits beeps and the Status
LED is flashing. This is the only time frame to accept the DAP code.
3.
Press the Egress Button (the button connecting EG IN and (-)GND) once to enable the keypad for accepting the
DAP code. The power-up beep stops after the Egress Button is pressed.
4.
Key in the DAP code 2 8 2 8 and validate it with * *. The Status LED is ON and the keypad is in programming
mode like when using the Master Code. It is ready to accept new programming data until you exit programming
mode.
Egress button
DAP code
Validation
Press once
2 8 2 8
* *