VELBUS INSTALLATION GUIDE
©2015 Velbus
59
www.velbus.eu
Note: The “
momentary
”
action means that the subject will follow the state of
the initiator. As long as the initiator is pressed (closed), the subject will be
pressed (closed) also. As long as the initiator is released (open), the subject will
be released (open) also.
The “Momentary” action, when used with multiple
initiators on the same subject, will function as a logical “OR”: as long as at least
one
of the initiators remains closed (“Pressed”), the subject will remain closed
(“Pressed”) also. Only when all initiators are open (“Released”) will the subject
be open (“Released”).
When the
“pump” and “heater”
channels close, the relays also close and thus
activate
the heating system. Once the “heater” and “pump” channels open
again, the relevant parts of the heating system will be deactivated too. As long
as at least one connected “pump” channel is closed
(“Pressed”), the “pump”
relay will also remain clo
sed. Only when all connected “pump” channels are
released, will the pump be deactivated.
More configuration options, e.g. hysteresis, sensor calibration, delays etc. are
accessible under the Temperature tab of the modules. For details, please refer
to
(product, FAQ and support pages).
CREATING AND MODIFYING PROGRAM STEPS
Program steps for input modules
All Velbus input modules can be programmed to activate, deactivate, lock,
unlock, press, long press or release their own channels at certain times. Time
settings can be fixed times, sunrise/sunset with or without offset, and more.
Program steps can be repeated daily, weekly, only on weekends, and so on.
Every input module has a built-in astronomical clock with sunset and sunrise
hours predefined.