5.2.1 Power supply connection
WARNING!
Work on electric supply lines
Work on electric supply lines must only be car-
ried out by a qualified electrician. Unplug the
mains disconnecting device prior to opening
the device. Danger to life!
The electrical connection and compliance of the specifications on
the type plate of the device and the local power supply must be
checked.
The device is designed to connect to a TN-S network. If a dif-
ferent network configuration is present, additional measures may
be required! In this case, please contact the qualified electrician
who is responsible for operation!
Connection to the mains must be protected on site. The regulations
of the local distribution system operators (DSO) must be observed.
Information on fusing can be found in the electrical connection data
and in the circuit diagram.
When laying the mains connection cable make sure that it is opti-
mally protected against mechanical damage and that there is no
risk of tripping over!
Make sure that the mains connection cable cannot contact any hot
surfaces!
WARNING!
Mains disconnecting device
The mains disconnecting device is the connector
of the mains connection cable. It must always be
freely accessible!
Unplug the mains disconnecting device to stop the
device in the event of danger.
WARNING!
Fixed connection
Fixed connection (without connector) of the device
is prohibited.
WARNING!
Modifications to the connector
Any person modifying the connector of the mains
connection cable or replacing it with another con-
nector is liable for proper clamping of the individual
cable wires and for any adverse consequences.
Installation
Connections > Power supply connection
30.09.2022
Steam generator VEIT SG67
27