6.3.4 Steam connection
The SF26 shirt finisher is connected to a water steam supply.
Machine working pressure
0.6 MPa (6 bar) at 158°C
Internal diameter of the steam
supply
1/2''
Steam must be connected according to the applicable technical
regulations.
The steam and condensate lines leading to the machine must be
provided with a stop valve. These stop valves must be installed
close to the machine so that the operating person may quickly dis-
connect the steam and condensate lines in the event of danger.
The steam and condensate lines must be laid such that there is no
risk of tripping over.
The water steam quality depends on the boiler water quality.
Boiler water requirements
Boiler water
Must be colourless, clear, and
free from undissolved material
and foaming agents.
ph value (at 25°C)
9 - 12
Total hardness
5 dH, max.
Electric conductivity (at 25°C)
100 µs, min.
CAUTION!
Risk of burns
There is a risk of skin burns from hot water steam
under pressure.
Connection only by qualified person.
Do not touch any components that carry water
steam or condensate.
Service the dirt separator at the water steam outlet
and the condensate drain according to the mainte-
nance schedule.
Installation
Installation > Steam connection
18.07.2017
Shirt finisher VEIT SF26
41
Summary of Contents for SF26
Page 85: ...12 1 Spare parts list Spare parts Spare parts list 18 07 2017 Shirt finisher VEIT SF26 85 ...
Page 86: ...Fig 31 From 10 2016 Spare parts Spare parts list 18 07 2017 Shirt finisher VEIT SF26 86 ...
Page 87: ...Fig 32 From 10 2016 Spare parts Spare parts list 18 07 2017 Shirt finisher VEIT SF26 87 ...
Page 90: ... with 3ph version only Spare parts Spare parts list 18 07 2017 Shirt finisher VEIT SF26 90 ...
Page 91: ...Spare parts Spare parts list 18 07 2017 Shirt finisher VEIT SF26 91 ...
Page 92: ...Spare parts Spare parts list 18 07 2017 Shirt finisher VEIT SF26 92 ...
Page 93: ...Spare parts Spare parts list 18 07 2017 Shirt finisher VEIT SF26 93 ...
Page 94: ...Spare parts Spare parts list 18 07 2017 Shirt finisher VEIT SF26 94 ...
Page 96: ...Fig 34 Cover from 10 2016 Spare parts Spare parts list 18 07 2017 Shirt finisher VEIT SF26 96 ...
Page 97: ...Spare parts Spare parts list 18 07 2017 Shirt finisher VEIT SF26 97 ...
Page 108: ...Spare parts Pneumatics diagram 18 07 2017 Shirt finisher VEIT SF26 108 ...
Page 109: ...12 3 Circuit diagram Spare parts Circuit diagram 18 07 2017 Shirt finisher VEIT SF26 109 ...