2 Panel Operation
25 SD780 Series Servo Technical Manual
2.4 Operations of Monitoring Display Un Group
The monitor displays can be used for monitoring the reference values, I/O signal status, and servo
internal status.
The panel operator displays the numbers which begin with Un, then let’s take this function as an
example to explain the operating method of the monitoring display: when the motor speed is
3000rpm:
Monitoring
display
Enter into
monitoring
Any
interference
MODE/SET
Long press
DATA/SHIFT
If you want the monitor to automatically display related information after the servo drive is powered
on, set PN003 (default 0xFFF) to a relevant value. For example, if you want the motor speed to
automatically display after the drive is powered on, set PN003 to 00000 (motor speed). For details
about the values of each monitoring information, see “Monitor Display”.