Chapter 8 Functional Parameter Table
ACH200 Series High Voltage Variable Frequency Speed Control System Operating Manual
91
F4.33
AC
drive-side
PWM
control
mode 1
LED one digit: carrier
associated with temperature
0: Temperature independent
1: temperature dependent
LED ten digits: carrier
associated
with
output
frequency
0: not related
1: related
LED
hundred
digits:
Reserved
LED thousand digits: PWM
modulation method
0:
Only
three-phase
modulation is used
1: Two-phase three-phase
modulation
automatic
switching
1110
●
△
0x421
F4.34
AC
drive-side
PWM
control
mode 2
LED
one
digit:
over-
commissioning switch
0: Off
1: open
LED
ten
digits:
dual
sampling dual update mode
switch
0: open
1: off
LED
hundred
digits:
deadband
compensation
switch
0: off
1: On
LED
thousand
digits:
Reserved
9110
●
△
0x422
F4.35
AC
drive-side
deadband
compensation
time
0~65535
306
●
△
0x423
8.1.6 F5 Motor Parameter Group
Functi
on
Code
Function
code
name
Setting value range and
definition
Factory
settings
Prop
erties
Address
F5.00
Motor type
0: Asynchronous motor
(AM)
1: Permanent magnet
synchronous motor (PM)
0
×
△
0x500
F5.01
Number of motor
poles
2~98
4
〇
△
0x501
F5.02
Motor rated power
0.1kW~1000.0kW
Model
Setting
※
〇
△
0x502
F5.03
Motor
rated
frequency
0.01Hz~
Maximum
frequency
Model
Setting
※
〇
△
0x503