Aqua-Hot Hydronic Heating System Shop Manual 09/04
®
SECTION 6: DIESEL-BURNER WIRING
Controller
Wiring
6.1
Diesel-Burner Controller
C-2 ( + ) Motor Circuit (Black Wire)
to Diesel-Burner.
B-2 ( - ) Battery Circuit (Brown Wire)
to JP-4 (Pin 4)
B-4 ( + ) Battery Circuit (Red Wire)
to JP-4 (Pin 3)
C-8 ( + ) Ignition Coil Circuit (Yellow Wire)
to Diesel-Burner.
C-6 ( + ) Flame Sensor Circuit (Green Wire)
to Diesel-Burner.
C-Plug
B-Plug
B-1 B-2
B-3 (+) Indicator Light Circuit (Blue
Wire)
to JP-4, (Pin 2).
B-1 ( + ) On / Off Switch
Circuit, with Low Voltage
Protection (Yellow Wire)
to
JP-4 (Pin 7)
.
B-3
B-4
B-6
C-1
C-8
C-7
C-6
C-4
C-2
C-5
B-6 ( - ) Indicator Light Circuit
(Green Wire)
to JP-4 (Pin 1).
C-5 ( - ) Ground Circuit (Brown Wire),
for
Diesel-Burner components, to Diesel-Burner.
C-7 ( + ) VDC / VAC Control Thermostat Circuit
(White Wire)
to JP-4 (Pin 6).
C-1 ( + ) VDC / VAC Control Thermostat
Circuit (Orange Wire)
to JP-4 (Pin 5).
NOTE:
Reference Figure 3 for all "JP" Plug
and Pin locations on the Electronic Controller
C-4 ( - ) VDC High-Limit Thermostat
Circuit (Blue Wire)
to Hydro-Hot’s
Boiler Tank.
Figure 8
C-5 (-) Ground Circuit (Black Wire)
�
to Hour Meter
C-2 (+) Motor Circuit (Red Wire)
to Hour Meter
Page 15