78
10 Supplement
VEGAPULS 69 • Modbus and Levelmaster protocol
47252-EN-210205
Max. power consumption
520 mW
Reverse voltage protection
Integrated
Potential connections and electrical separating measures in the instrument
Electronics
Not non-floating
Reference voltage
7)
500 V AC
Conductive connection
Between ground terminal and metallic process fitting
10.2 Radio astronomy stations
Certain restrictions on the use of VEGAPULS 69 outside closed vessels result from the radio
license. You can find these restrictions in chapter "
Radio license for Europe
". Some of these restric-
tions have to do radio astronomy stations. The following table states the geographic positions of
radio astronomy stations in Europe:
Country
Name of the Station
Geographic Latitude
Geographic Longitude
Finland
Metsähovi
60°13'04'' N
24°23'37'' E
France
Plateau de Bure
44°38'01'' N
05°54'26'' E
Germany
Effelsberg
50°31'32'' N
06°53'00'' E
Italy
Sardinia
39°29'50" N
09°14'40" E
Spain
Yebes
40°31'27" N
03°05'22" W
Pico Veleta
37°03'58" N
03°23'34" W
Sweden
Onsala
57°23’45" N
11°55’35" E
10.3 Device communication Modbus
In the following, the necessary device-specific details are shown. You can find further information of
Parameters for the bus communication
The VEGAPULS 69 is preset with the following default values:
Parameter
Configurable Values
Default Value
Baud Rate
1200, 2400, 4800, 9600, 19200
9600
Start Bits
1
1
Data Bits
7, 8
8
Parity
None, Odd, Even
None
Stop Bits
1, 2
1
Address range Modbus
1 … 255
246
Start bits and data bits cannot be modified.
General configuration of the host
The data exchange with status and variables between field device and host is carried out via
7)
Galvanic separation between electronics and metal housing parts