1 For your safety

VEGABAR 83 • Modbus and Levelmaster protocol

46318-EN-220624

1  For your safety

1.1  Authorised personnel

All operations described in this documentation must be carried out 

only by trained, qualified personnel authorised by the plant operator.
During work on and with the device, the required personal protective 

equipment must always be worn.

1.2  Appropriate use

The VEGABAR 83 is a pressure transmitter for process pressure and 

hydrostatic level measurement. 

You can find detailed information about the area of application in 

chapter " 

Product description

". 

Operational reliability is ensured only if the instrument is properly 

used according to the specifications in the operating instructions 

manual as well as possible supplementary instructions.

1.3  Warning about incorrect use

Inappropriate or incorrect use of this product can give rise to applica-

tion-specific hazards, e.g. vessel overfill through incorrect mounting 

or adjustment. Damage to property and persons or environmental 

contamination can result. Also, the protective characteristics of the 

instrument can be impaired.

1.4  General safety instructions

This is a state-of-the-art instrument complying with all prevailing 

regulations and directives. The instrument must only be operated in a 

technically flawless and reliable condition. The operator is responsi

-

ble for the trouble-free operation of the instrument. When measuring 

aggressive or corrosive media that can cause a dangerous situation 

if the instrument malfunctions, the operator has to implement suitable 

measures to make sure the instrument is functioning properly.

The safety instructions in this operating instructions manual, the na

-

tional installation standards as well as the valid safety regulations and 

accident prevention rules must be observed by the user.

For safety and warranty reasons, any invasive work on the device 

beyond that described in the operating instructions manual may be 

carried out only by personnel authorised by the manufacturer. Arbi-

trary conversions or modifications are explicitly forbidden. For safety 

reasons, only the accessory specified by the manufacturer must be 

used.

To avoid any danger, the safety approval markings and safety tips on 

the device must also be observed.

1.5  EU conformity

The device fulfils the legal requirements of the applicable EU direc

-

tives. By affixing the CE marking, we confirm the conformity of the 

instrument with these directives.

Summary of Contents for VEGABAR 83

Page 1: ...Quick setup guide Pressure transmitter with metallic measuring cell VEGABAR 83 Modbus and Levelmaster protocol Document ID 46318...

Page 2: ...ule 10 5 1 Insert display and adjustment module 10 5 2 Parameter adjustment Quick setup 10 5 3 Parameter adjustment Extended adjustment 12 5 4 Menu overview 13 6 Set up with smartphone tablet PC noteb...

Page 3: ...instructions This is a state of the art instrument complying with all prevailing regulations and directives The instrument must only be operated in a technically flawless and reliable condition The op...

Page 4: ...romagnetic compatibility of equipment NE 53 Compatibility of field devices and display adjustment components NE 107 Self monitoring and diagnosis of field devices For further information see www namur...

Page 5: ...l contains the serial number of the instrument With it you can find the following instrument data on our homepage Product code HTML Delivery date HTML Order specific instrument features HTML Operating...

Page 6: ...plies mainly to outdoor installations in areas where high humidity is expected e g through cleaning processes and on cooled or heated vessels Note Make sure that during installation or maintenance no...

Page 7: ...ould hear it snap in Proceed as follows 1 Unscrew the housing lid 2 Loosen compression nut of the cable gland and remove blind plug 3 Remove approx 10 cm 4 in of the cable mantle signal output strip a...

Page 8: ...ble entry gland The seal ring must completely encircle the cable 10 Screw the housing lid back on The electrical connection is finished Information The terminal blocks are pluggable and can be removed...

Page 9: ...em VEGABAR 83 Modbus and Levelmaster protocol 46318 EN 220624 Terminal Function Polarity 1 Voltage supply 2 Voltage supply 3 Modbus signal D0 4 Modbus signal D1 5 Function ground when installing ac co...

Page 10: ...nics in the desired position and turn it to the right until it snaps in 3 Screw housing lid with inspection window tightly back on Disassembly is carried out in reverse order The display and adjustmen...

Page 11: ...pplication different adjustment units are available Position correction In this menu item you compensate the influence of the installation position of the instrument offset on the measured value Zero...

Page 12: ...ee following example 2 1 100 0 5 m 196 9 Fig 7 Parameter adjustment example Min max adjustment level measure ment 1 Min level 0 corresponds to 0 0 mbar 2 Max level 100 corresponds to 490 5 mbar If the...

Page 13: ...tems in the main menu item Setup should be selected one after the other and provided with the correct parameters If possible go through the items in the given sequence The submenu points are described...

Page 14: ...nostics Menu item Parameter Default value Device status Peak value Pressure Current pressure measured value Pointer function temp Temperature Actual measuring cell and electronic tem perature Simulati...

Page 15: ...ivate Bluetooth 1 Switch On Bluetooth active Off Bluetooth not active The security concept of Bluetooth operation absolutely requires that the default setting of the sensor PIN be changed This prevent...

Page 16: ...otebook Start PACTware and the VEGA project assistant Select the device search via Bluetooth and start the search function The device auto matically searches for Bluetooth capable devices in the vicin...

Page 17: ...17 6 Set up with smartphone tablet PC notebook via Bluetooth VEGABAR 83 Modbus and Levelmaster protocol 46318 EN 220624 Fig 9 Example of an app view Setup sensor adjustment App view...

Page 18: ...homepage Electromechanical data version IP66 IP67 and IP66 IP68 0 2 bar 2 Options of the cable entry Cable entry M20 x 1 5 NPT Cable gland M20 x 1 5 NPT cable see below table Blind plug M20 x 1 5 NPT...

Page 19: ...19 Notes VEGABAR 83 Modbus and Levelmaster protocol 46318 EN 220624...

Page 20: ...ing scope of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change withou...

Reviews: