Vega NB-15 / User Manual
18
Revision 02 – 28 April 2021
“VEGA NB-15” TAB
The “Vega NB-15” tab contains detail information about the connected device, its
sensors and inputs.
Network
– displays the current parameters of the connection and allows to control it.
Buttons in this block have logic like INIT button on the board.
SQ parameter – Signal Quality – may be from 0 to 31 while connection is on, and 99
value means the connection absent. Table of values is shown below.
Value in program
Signal Quality, dBm
0
-113 and lower
1
-111
2…30
-109…-53
31
-51 and more
99
No connection
100
-116 and lower
101
-115
102…190
-114…-26
191
-25 and more
199
No connection
1-Wire
– settings of connection external temperature sensors and it’s readings. For
adding a sensor in system, you need to switch ON the auto add mode. Sensors get numbers in
order which them were connected. After switching the auto add mode ON the device starts
search the new sensors on the bus. When new sensor is found, the device adds it in memory
and the auto add mode OFF automatically. To add the next sensor, you need to switch the auto
add mode ON again. All sensors may be removed from the memory with button “Delete all
sensors”.