LORAWAN CONVERTER 

VEGA TP-11 

User Manual 

 

 

 

 

 

 

 

 

 

Summary of Contents for TP-11

Page 1: ...www vega absolute ru LORAWAN CONVERTER VEGA TP 11 User Manual...

Page 2: ...V External devices connection was added 04 10 01 2018 PKP Changes in the communication protocol Values of basic settings bit field decoding table corrected 05 19 06 2018 TII Changes in parts Contacts...

Page 3: ...tial startup 12 External devices connection 13 Connecting via USB 14 4 VEGA LORAWAN CONFIGURATOR 15 Interface of the application 15 Connection to the device 16 Device info tab 17 LoRaWAN settings tab...

Page 4: ...o provide the stable radio between the gateway and the end device it is recommend avoiding the device installation in the places which are barriers for the radio signal getting through like a reinforc...

Page 5: ...provides connected sensors with 24 V power via 4 20 mA interface Vega TP 11 has two open drain outputs so it can be used as a control device Also device has two security inputs COMUNICATION AND DATA C...

Page 6: ...sends all accumulated packets to the network in order from the earliest to the latest There are no checks of package delivery in this mode There are no non transmitted messages in the device memory T...

Page 7: ...of manufacture o QR code containing DevEUI for automatized count Sticker located in three places on device case in factory certificate and on the packing box Besides there is an additional sticker loc...

Page 8: ...Data collection period 5 15 30 minutes 1 6 12 or 24 hours Memory amount for storing packets 200 packets Antenna connector SMA Sensitivity 138 dBm Radio coverage in restrained urban conditions max 5 k...

Page 9: ...UT_1 Open drain output 1 3 VPWR Power 4 Power 5 CL 4 20 mA 6 CL 4 20 mA 7 COUNT_2 Security input 2 8 Ground 9 COUNT_1 Security input 1 10 Ground Ground contacts 8 and 10 are used for connection of sec...

Page 10: ...y life of the converter the 24 V supply voltage is not continuously supplied The 24 V voltage is applied to the 4 20 mA device a few seconds before the polling is performed so that the sensor can turn...

Page 11: ...e changed LED signal Meaning Series of short flashings Linking to the network One long flashing The device connected to the network and is in active mode Three long flashings Linking to the network is...

Page 12: ...f the methods using Vega LoRaWAN Configurator application See part 4 1 ABP After pressing the start button the device immediately starts working in the Active mode 2 OTAA After pressing the start butt...

Page 13: ...s entered in the network Device EUI Application EUI and Application Key for OTAA or Device address Application session key and Network session key for ABP EXTERNAL DEVICES CONNECTION The actuators are...

Page 14: ...river for the COM port stsw stm32102 which can be downloaded from iotvega com After running the executable file VCP_V1 4 0_Setup exe the installer window will appear In this window you need to click N...

Page 15: ...c settings advanced settings and the ability to check the coverage area of the signal from the gateways are available Next the work of the application is considered in the Expert mode INTERFACE OF THE...

Page 16: ...ce perform the following steps 1 Connect the USB cable to the device 2 Start the Vega LoRaWAN Configurator application 3 Click the Connect button in the menu on the left The application automatically...

Page 17: ...AN network with OTAA method Over The Air Activation is displayed Key management not displayed in the Simple mode allows you to change the factory keys to register the device on the network and reset t...

Page 18: ...ocedure will occur Link check not displayed in the Simple mode when pressed the device sends a special signal to the LoRaWAN network in response to which the network informs it of the number of gatewa...

Page 19: ...8 based In the device frequency plan only those channels are active by default on which sending requests for connection to the network join channels The remaining channels that the device should use c...

Page 20: ...retry sending the packet until it receives the server confirmation or until the Uplink number of transmission is over see below ADR this option activates the Adaptive Data Rate algorithm for automatic...

Page 21: ...work while OTAA mode active The second window always opens after 1 second after the first Uplink number of transmission not displayed in the Simple mode if the Confirmed uplinks function is disabled t...

Page 22: ...djusted to this value when sending packets to the LoRaWAN network This option can be changed by the network server TX datarate not displayed in the Simple mode the device transmission datarate at whic...

Page 23: ...ent high threshold parameters allow setting current value range when the measurements are out of which the device will switch in alarm mode Data collection period may be setting independently for that...

Page 24: ...be adjusted from 5 minutes to 24 hours Data transfer is carried out by a random time at the selected period At the next communication session the device starts sending accumulated packets with readin...

Page 25: ...32 1 byte Current device temperature int8 2 bytes Current low threshold m 100 uint16 2 bytes Current high threshold m 100 uint16 1 byte Reason of sending message uint8 1 byte TP 11 inputs outputs stat...

Page 26: ...5 uint8 4 bytes Time of the modem at a moment of the packet transmission unixtime UTC uint32 After receiving this type of package the application can send to modem the packet with time correction 4 Se...

Page 27: ...kage TP 11 will close the correspond output and transmits the packet with current readings 3 Output off command send by application on LoRaWAN port 2 Size in bytes Field description Data type 1 byte P...

Page 28: ...upported by the device but only the part that needs to be changed Table of ID of TP 11 parameters and these possible values ID of parameter Description Data length Possible values 4 Confirmed uplinks...

Page 29: ...Revision 09 08 April 2020 29 6 15 minutes 7 30 minutes 55 Time zone in minutes 2 bytes from 720 to 840 85 Current low threshold in mA 100 2 bytes from 200 to 2500 86 Current high threshold in mA 100 2...

Page 30: ...RTATION REQUIREMENTS Vega TP 11 shall be stored in the original packaging in heated room at temperatures 5 to 40 and relative humidity less than 85 The converter shall be transported in covered freigh...

Page 31: ...TP 11 User Manual Revision 09 08 April 2020 31 7 CONTENT OF THE PACKAGE Vega TP 11 device is delivered complete with Converter Vega TP 11 1 pc Antenna LoRa 1 pc Screw 3 16 6 pcs Factory certificate 1...

Page 32: ...ecified in this user manual Warranty does not apply to power supplies of devices sending more than 20 000 packets the device with mechanical electrical and or other damages and defects caused by viola...

Page 33: ...Vega TP 11 User Manual Revision 09 08 April 2020 33 vega absolute ru Operation Manual Vega Absolute LLC 2017 2020...