Error Injection
After pressing
Start
, error injection can be enabled by pressing the
Error Inj.
button on the right
side of the screen.
6.2.1.4 Alarm Injection Settings
Alarm injection can be performed during a test. The type of alarms and alarm injection are configured in the Alarm Injection tab. Once the test is running, alarm injection can
be performed by pressing the
Alarm Inject
button on the right side of the screen.
Alarm Type:
Local Fault, Remote Fault, PCS-HI-BER, PCS-LOBL
Alarm Flow:
The alarm flow determines how the selected alarms will be injected. A specific Count or Conitnue (continuous) can be selected.
Alarm Length:
1s, 10s, or 100s.
BERT Setup - Alarm Injection
6.2.1.5 Starting/Stopping a BERT
UX400 10G e-Manual D07-00-058P RevA00
Page 48 of 209