8.1.2 Results > Errors/Alarms Page 1
The Error/Alarm tab brings up several pages showing the errors and alarm status. Page 1 of 4 (Dual DS1 mode, Page 1 of 6)
provides an overview of all the Errors and Alarms applicable to the signal or network under test. The color of the page tab is
normally blue, however it will turn red when an alarm / error condition has been detected or recorded.
The soft LEDs on screen are arranged logically and will depend on signal hierarchy, structure, payload and framing selected. The
soft LEDs have a tri-color function;
-
Green:
No error or alarm is present
-
Red:
An error or alarm condition is detected and is currently present
-
Yellow:
Indicates a history condition. An error or alarm was detected during the measurement interval but it is no longer
present or active
Dual DS1 Mode
TX150 e-Manual D07-00-023 Rev A02
Page 33 of 107