MX120 Introduction:
The MX120 is part of the MX product family - in essence the MX120 is similar to having two MX100's in one chassis. The default
configuration of the MX120 allows for single port operation (same as the MX100) and pass through monitor mode. Pass through
monitor mode enables bidirectional monitoring between the two 1000Base-X ports or the two 10/100/1000 Base-T ports.
Dual Port operation
When the dual port interfaces and software options are enabled, the test set can operate a combination of two ports at the
same time with the following physical port operation combinations:
Port 1 10/100/1000Base-T and Port 2 10/100/1000Base-T (copper ports only)
Port 1 1000Base-X and Port 2 1000Base-X (fiber ports only)
Port 1 10/100/1000Base-T and Port 1 1000Base-X (copper and fiber port combination)
Port 1 (Throughput) and Port 2 (Throughput)
Port 1 (Loopback) and Port 2 (any application)
Port 1 (any application) and Port 2 (Loopback)
Port 1 (Loopback) and Port 2 (Loopback)
Test Applications:
When the unit is operating in any of the physical ports above, each port (single or dual) will be
enabled to run the same test application.
BERT
- Unframed / Framed Layer 1, and Framed Layer 2/3 Ethernet traffic generation with user selectable test
pattern for Bit Error Rate analysis.
RFC 2544
- Throughput, Back-to-Back, Frame Loss and Latency conformance tests in accordance with RFC 2544
specifications.
Throughput
- Ethernet traffic generation and analysis with multiple-streams to verify network throughput and jitter
Loopback
- Loop back the transmitted data while swapping the source and destination addresses of the MAC, IP
and UDP layers.
When the MX120 is operating in any of the physical port combinations described above, each port will by enabled to run the same
application (BERT, RFC 2544, Throughput). The configuration parameters (header, bandwidth, etc) for each application (on each of
the ports) are completely independent from one another - for example;
Port 1 (RFC 2544) and Port 2 (RFC 2544)
Port 1 (BERT) and Port 2 (BERT)
MX120 - Dual Port Test Application
2.0 About this User Manual
Every effort was made to ensure that the information contained in this user manual is accurate. Information is subject to change
without notice and we accept no responsibility for any errors or omissions. In case of discrepancy, the web version takes
precedence over any printed literature.
(c) Copyright 2006-2007 VeEX Inc. All rights reserved. VeEX, VePAL are registered trademarks of VeEX Inc and/or its affiliates in
the the USA and certain other countries. All trademarks or registered trademarks are the property of their respective companies.
No part of this document may be reproduced or transmitted electronically or otherwise without written permission from VeEX Inc.
MX100/120 e-Manual D07-00-004 Rev A04
Page 8 of 115