Ethernet
© VeEX Inc. All Rights Reserved.
120
Results
Results - Config. Tests - Service 1
To run the test, make sure that traffic is being looped back at the far-end of the network under test.
Configuration Test
The
Config. Tests
tab lists the Pass/Fail status of each service and test. Tapping on the table brings up a
screen with
CIR
and enabled tests including
CIR/EIR, CBS, EBS,
and
Policing Test
results for the chosen
Service
.
The test tabs display min, mean, and max values for
IR Mbps
,
FTD
,
FDV
,
Frame Loss Count
, and
Frame Loss Ratio (%).
If Step Load was selected for the CIR Test, these values will be displayed for each
step. If any measured values do not meet the service test parameters set in the Bandwidth and Threshold tabs,
the test fails.
l
IR Mbps:
Information Rate. Measures the average Ethernet frame rate starting at the MAC address
field and ending at the CRC.
l
FTD:
Measures the time that the frames can take to travel from source to destination.
l
FDV:
Measures the frame jitter.
l
Frame Loss Count:
Counts the number of lost frames.
l
Frame Loss Ratio:
Ratio of lost frames to the total transmitted frames.
Summary of Contents for MTX150 Series
Page 1: ...MTX150x User Manual Multi Service Installation Maintenance Test Set P N D07 00 148P Rev B00 ...
Page 11: ...Customer Care 303 Table of Contents VeEX Inc All Rights Reserved 11 ...
Page 171: ...171 VeEX Inc All Rights Reserved Ethernet V FTP Setup Download V FTP Download Results SyncE ...
Page 246: ...Common Functions VeEX Inc All Rights Reserved 246 Bluetooth Devices Bluetooth Scan ...
Page 248: ...Common Functions VeEX Inc All Rights Reserved 248 Bluetooth Devices Bluetooth Scan ...
Page 267: ...267 VeEX Inc All Rights Reserved Common Functions ...