8.6 Bidirectional OTDR Testing (X-view)
When Bidirectional fiber testing results are available, the OTDR can be used to view the
results using the X-format. The OTDR results table will be unidirectional, meaning results can
be viewed from one trace at a time. Use the green arrow in thumbnail view to switch active
trace/even table results.
In some cases, a more detailed analysis may be needed. This can be
accomplished by averaging the test results of both traces. Results are averaged
to counteract variation in attenuation at connector junctions between fiber
sections.
Fiberizer Cloud or Fiberizer Desktop Plus software is recommended to:
•
Generate test reports that will include the results table that shows both
individual results and averaged bidirectional results, along with traces in
an X-view format.
•
Automate bidirectional test reports for a batch of fiber strands, instead of
individual strands at a time.
For more information on Fiberizer Cloud or Fiberizer Desktop Plus, go to
To create a bidirectional X-view screen:
1. Before saving bidirectional test results, configure
Autosave
settings so that it is easy to
track bidirectional results. In the
Setup
tab, tap
Autosave
. The
Autosave Parameters
window appears.
•
Set
Increment
to
Trace ID
and
Other
tab to enter
Origin
and
Termination
sites.
•
The
Trace ID
label should reflect the physical location for each direction (e.g. first trace
labelled “origin_end” and the second opposite end labelled “end_origin”).
Do not use “-“ in the
Trace ID
field.
•
Reset or Force the
Trace Index
counter number to the fiber port you are testing at;
otherwise, it will continue incrementing from the previous test. To change the number,
tap
Trace Index
.
Summary of Contents for FX150
Page 14: ...OTDR Series e Manual RevE00 Page 14 of 128 TX3x0S Top View RXT 4100 OTDR Module ...
Page 17: ...OTDR Series e Manual RevE00 Page 17 of 128 5 3 MTTplus Overview 5 3 1 MTTplus Side View ...
Page 19: ...OTDR Series e Manual RevE00 Page 19 of 128 5 4 RXT Overview ...
Page 50: ...OTDR Series e Manual RevE00 Page 50 of 128 Analysis Report pdf format ...
Page 117: ...OTDR Series e Manual RevE00 Page 117 of 128 Results tab Wavelength Trace ...