18
Mag Probe Assembly
The following assembly instructions are for Global Mag Plus and Mag Plus probes. For other probe types follow
assembly instructions included with probe.
Attaching Probe Canister Spacer Rings
Open the probe shipping carton so that you have access to the probe. Also open the installation kit.
For 3- and 4-inch risers
After adjusting the spacers for a 3- or 4-inch riser, install the two spacer rings as shown in Figure 12. Note: you
must slide the bottom spacer up over the probe and onto the lower end of the canister.
For 2-inch risers
Install the two canister insulator sleeves onto the probe canister as shown in Figure 13. Note: you must slide the
bottom sleeve up over the probe and onto the lower end of the canister.
Assembling Floats onto Probe Shaft
The Product float, Water or Water/Density Float and Boot from the Probe Installation Kit are assembled on the
probe shaft in the exact sequence and orientation shown in Figure 14.
IMPORTANT! Failure to push the boot as far as possible onto the probe shaft could cause the boot and float(s) to
fall into the tank. The boot must be pushed on until it “locks” on the probe shaft. Also, water floats must be
installed, if ordered, for the probe to operate correctly.
Handle the probe carefully. Striking or dropping the probe will result in loss of calibration and could cause
permanent damage.
Attaching Cable Connector to Probe Canister
Attach the connector end of the probe cable to the threaded connector on top of the probe canister and tighten
down the integral nut.
This completes the probe assembly. Save the remaining kit components. They will be needed to install the probe
into the tank.