RS-232 Commands
Function Code: A10
55
Function Code: A10
Function Type:
Probe Last Sample Buffers
Version 1
Command Format:
Display:
<SOH>IA10TT
Computer:
<SOH>iA10TT
Typical Response Message, Display Format:
<SOH>
IA10TT
TT PP nnnnn
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
ssss.sss
<ETX>
Notes:
1.
TT
-
Tank Number (Decimal, 00 = all)
2.
PP
-
Probe Type:03 - MAG1
3.
nnnnn
-
Sample Number (Decimal)
4.
ssss.sss
-
Probe Data (Decimal)
Typical Response Message, Computer Format:
<SOH>iA10TT0000000000TT0PPSSSSNNFFFFFFFF...
TT0PPSSSSNNFFFFFFFF...&&CCCC<ETX>
Notes:
1.
0000000000
- Not Used
2.
TT
- Tank Number (Decimal, 00 = all)
3.
0
- Not used
4.
PP
- Probe Type: 03 - MAG1
5.
SSSS
- Sample Number (Hex)
6.
NN
- Number of eight character Data Fields to follow (Hex)
7.
FFFFFFFF
- Probe Data (ASCII Hex IEEE float)
8.
&&
- Data Termination Flag
9.
CCCC
- Message Checksum