Initial Setup Of The Console Using Workflow Wizard
Setup>System>Security
57
System Administration>Users Admin
- Concluded
Setup>System>Security
3. Touch
to save your entry. Touch
and touch the
X
in the upper
right corner to exit without saving changes.
Deleting a User
(available to an Ad
m
inistrator user only)
NOTE: You can not delete or reassign the role of the last Ad
m
in user - there
has to be at least one user with an Ad
m
in role.
1. Select a user to delete (a check
m
ark appears next to the entry, and then
select
Actions>Delete User
.
2. Touch
to delete selected role or
to cancel deletion. .
This screen lets you enable the front panel security feature which requires a password for a
user to login to the console. With this feature disabled (i.e., no password required), all users
can access all screens. When enabled, users
m
ust login with the appropriate password to
gain access to the progra
m
s they are allowed to view (as set up in the“Syste
in” screen). This is helpful when you want to li
m
it access to sensitive areas
of the syste
m
, such as the setup and diagnostic screens.
NOTES:
• This feature cannot be enabled until an Ad
m
inistrator account has been created (done in
the Syste
m
Ad
m
inistration>Users Ad
m
in screen).
• Once the Front Panel Security field is enabled, you
m
ust enter the correct password or you
will re
m
ain in the logged-out
m
ode. In the logged-out
m
ode, you can only view a very li
m
-
ited nu
m
ber of screens (such as syste
m
status).
Front Panel Security
Touch to enable or disable the Front Panel Security feature.
Serial Command Port (TCP/IP Interface)
Default is enabled.
This will co
m
pletely disable access to the serial co
mm
and
port via Ethernet. The port is defined under Setup > Co
m
-
m
unication > Ethernet Port Serial Co
mm
and Port (default is
10001).
Serial co
mm
ands should still continue to function via the
physical RS232 interface (Serial COM Port 1 & 2).
•Serial Co
mm
and Port: This is the port
m
any co
m
panies use
for entering RS232/Serial co
mm
ands via TCP/IP port 10001.
Disabling this will prevent re
m
ote syste
m
s fro
m
changing
para
m
eters on the gauge.
User Admin via Web
Default is enabled
The “User Ad
m
in via Web” setting will allow an Ad
m
inistra-
tor to provide user ad
m
inistration via the web.
Today, it is possible to configure user’s via web. The “user
Manage
m
ent via Web” control will allow the syste
m
ad
m
in-
istrator to enable / disable the “Users Ad
m
in” link on the
screen Syste
m
Ad
m
inistration > Users Ad
m
in. Note: this
only enables / disables access to Syste
m
Ad
m
inistration >
Users Ad
m
in.
The users will still be able to login to the Web, if they have