background image

  

Introduction

Safety Warnings

2

Safety Warnings

Related Documents

DOCUMENTS REQUIRED TO INSTALL EQUIPMENT

This equipment must be installed according to the applicable installation document:

REFERENCE MANUALS

577014-073

TLS-450PLUS Console Site Prep And Installation Manual

WARNING

This console contains high voltages which can be lethal. It is also connected to low 
power devices that must be kept intrinsically safe.

FAILURE TO COMPLY WITH THE FOLLOWING WARNINGS AND SAFETY 
PRECAUTIONS COULD CAUSE DAMAGE TO PROPERTY, ENVIRONMENT, 
RESULTING IN SERIOUS INJURY OR DEATH.

1. Turn off and tag power at the circuit breaker. Do not connect the console AC 

power supply wires at the breaker until all devices are connected.

2. Attach conduit from the power panel to the console's Power Area knockouts 

only.

3. Comply with all applicable codes including: the National Electrical Code; 

federal, state, and local codes; and other applicable safety codes.

Connecting power wires to a live circuit can cause electrical shock that may result in 
serious injury or death. 

Routing conduit for power wires into the intrinsically safe compartment can result in 
fire or explosion resulting in serious injury or death.

Equipment

ATEX

Descriptive System

IECEx

Descriptive System

UL/cUL 

Control Drawing

Document No.

Document No.

Document No.

Associated Apparatus

TLS-450PLUS

331940-006

331940-106

331940-008

Intrinsically Safe Apparatus for Wireless Applications

Tank Gauge Accessories

331940-005

331940-105

331940-012

OFF

Summary of Contents for TLS-350l

Page 1: ...Manual No 577014 074 Revision A Upgrade Instructions TLS 350 To TLS 450PLUS Console...

Page 2: ...ur Terms and Conditions VEEDER ROOT S PREFERRED CARRIER 1 Contact Veeder Root Customer Service at 800 873 3313 with the specific part numbers and quantities that were missing or received damaged 2 Fax...

Page 3: ...ions Against Static Electricity 5 Comm Module Slots And Configurable ports 5 Connecting The Power Wires To The Console 8 Initial Startup Procedure For Sites Without Wireless 2 devices 10 For Sites Wit...

Page 4: ...ation checkout startup programming system tests troubleshooting service techniques and operations training on the designated system Wireless 2 Tall Tank Warranty Registrations may only be submitted by...

Page 5: ...AC power supply wires at the breaker until all devices are connected 2 Attach conduit from the power panel to the console s Power Area knockouts only 3 Comply with all applicable codes including the N...

Page 6: ...ally safe wires are labeled and their polarity if applicable noted before removing them Verify all non intrinsically wiring connections are labeled before removing them 5 Unplug the high and low volta...

Page 7: ...ight Connecting Wiring To Console Modules Refer to the appropriate Control Drawing on page 2 to identify modules that can be installed in the console and the designated devices that can be connected t...

Page 8: ...ts 1 3 are available for user selectable Comm modules Figure 3 Slots 4 and 5 are fixed and can not be changed see Figure 4 2 Important to avoid attaching a Comm cable to a non configurable NC port ide...

Page 9: ...6 18 35 BOTTOM VIEW tlsng dim eps Mounting flanges w 1 4 x 3 8 slotted hole typ 4 places 3 1 8 1 2 TYP 5 925 0 65 4 5 8 3 1 8 3 1 8 3 1 8 TOP VIEW Conduit entries to Module bay 3 4 1 I P S knockouts t...

Page 10: ...3 2 1 4 4 5 L1 G N L2 Comm module clamp securing screw Slots 1 3 Selectable Comm Modules see Figure 3 Slots 4 and 5 Fixed Comm Modules see Figure 4 Slots 1 4 Any combination of USM I O MDIM or LVDIM...

Page 11: ...The console is prepunched for conduit This should be large enough since the only wires going through this conduit will be for L1 neutral panel ground and earth ground and possibly 1 relay Refer to man...

Page 12: ...elf adhesive label Re energize the circuit and start up the unit L1 N L2 L1 G L2 To 240 Vac breaker in power panel 240 Vac Power Input 120 Vac Power Input L1 BLK N L2 WHT N L2 BLK G GRN Barrier G Y L1...

Page 13: ...LS 450PLUS and wait 5 minutes until the console s Discover Mode is complete 2 Setup the TLS 450PLUS FOR SITES WITH WIRELESS 2 DEVICES 1 Power up all wireless devices 2 Power up the TLS RF console and...

Page 14: ...For technical support sales or other assistance please visit www veeder com...

Reviews: