Operating Conditions
Symbol
Parameter
Min
Typ
Max
Unit
VCC
DC Power Output (VBUS) *
4.5
5.0
5.5
V
Ta
Ambient Operating Temperature Range
-40
25
85
°C
(*) Output current might be limited by USB Host and internal adapter settings
Electrical Characteristics
These are applicable to pins RXD, CTS.
Symbol
Parameter
Min
Typ
Max
Unit
V
IH
Input High Voltage
1.5
3.3
V
V
IL
Input Low Voltage
0.0
1.0
V
These are applicable to pin TXD, RTS.
Symbol
Parameter
Min
Typ
Max
Unit
V
OH
Output High Voltage (I
OH
= -1 mA)
2.2
2.7
3.2
V
V
OL
Output Low Voltage (I
OL
= 2 mA)
0.3
0.5
V
QuickStart Instructions
Software Setup
The first time you want to use the QuickUSB you need to install the required software drivers for your
Operating System. Please follow this procedure (one-time only):
1. Plug the USB end of the cable to your PC and leave the other end unconnected
2. If you have a recent OS version please allow the system to search for updated drivers:
a. If the setup was successful, unplug the cable, the procedure is complete
b. If the setup failed, unplug the cable and continue to the next step
3. Download the latest official drivers for your OS version from the
4. Run the driver setup package, or follow any alternate installation procedure accompanying the
download
5. After the software setup is complete go back to step 1 above, the OS should now be able to find the
required drivers automatically
Using the Adapter
Once the required software drivers are correctly installed and configured by the Operating System, you
should not need to repeat the above procedure anymore.
Just plug the cable on the target board first, then plug the USB connector to a free port on your PC.
The adapter will be visible as a new USB Serial Port device and a virtual COM port on Windows. This COM
port number is the one to use with the EasyVR Commander.