VA Motion Controller Programming Manual
139
When the contact
C016
is
ON
,
the instruction is executed, and
two
16
-bit integers are added to
obtain a
16
-bit integer;
Execution
result:
VO43+V044=V045
10.1.4 ADD_T_T (Time Addition Instruction )
IL
programming language
LD, FBD
programming language
Function:
ADD_T_T
instruction is used to find the sum of two time data
LD IN1
ADD_T_T IN2
ST OUT
ST
programming language
OUT:=ADD_T_T
(
IN1
,
IN2
)
Note :
IL, ST
language programming needs to insert variables
IN1, IN2
and
OUT
or use
constants in the current
POU
variable worksheet
ADD_T _T
instruction processing data types
Input and output
type of data
description
IN1
TIME
Addend
IN2
TIME
Addend
OUT
TIME
And,
OUT=IN1+IN2
program demonstration
Find the value of
T#1s+T#50ms
description
When
C001
is
ON
, the instruction is
executed, and the time data types are added
to be added;
Execution result:
V002+V003=V004
10.1.5 AND ( Logic and Instruction )
IL
programming
language
LD, FBD
programming language
Function:
AND
instruction is used for the logical AND operation of two data
LD IN1
Summary of Contents for VEC-VA Series
Page 1: ......
Page 25: ...VA Motion Controller Programming Manual 20 Word STRING String VECTOR ...
Page 90: ...VA Motion Controller Programming Manual 85 ...
Page 116: ...VA Motion Controller Programming Manual 111 ...
Page 139: ...VA Motion Controller Programming Manual 134 ...
Page 274: ...VA Motion Controller Programming Manual 269 ...
Page 329: ...VA Motion Controller Programming Manual 324 ...
Page 342: ...VA Motion Controller Programming Manual 337 2 Motion curve and timing diagram ...
Page 352: ...VA Motion Controller Programming Manual 347 2 Motion curve and timing diagram ...
Page 357: ...VA Motion Controller Programming Manual 352 2 Motion curve and timing diagram ...
Page 372: ...VA Motion Controller Programming Manual 367 2 Timing and motion profiles of FIG ...
Page 386: ...VA Motion Controller Programming Manual 381 2 the motion profile and timing ...
Page 444: ...VA Motion Controller Programming Manual 439 ...
Page 460: ...VA Motion Controller Programming Manual 455 ...
Page 461: ...VA Motion Controller Programming Manual 456 2 a timing graph and ...
Page 481: ...VA Motion Controller Programming Manual 476 ...
Page 543: ...VA Motion Controller Programming Manual 538 ...
Page 561: ...VA Motion Controller Programming Manual 556 ...
Page 597: ...VA Motion Controller Programming Manual 592 ...
Page 603: ...VA Motion Controller Programming Manual 598 ...
Page 607: ...VA Motion Controller Programming Manual 602 ...
Page 610: ...VA Motion Controller Programming Manual 605 ...
Page 613: ...VA Motion Controller Programming Manual 608 ...
Page 648: ...VA Motion Controller Programming Manual 643 Mode 1 is not available ...