background image

TRIMMER ADJUSTMENT

To adjust the humidistat and timer trimmers,

remove the front cover of the fan (Fig 2) to

access the trimmers. 
The humidistat (HY) can be adjusted

between 40% and 90% relative humidity.

Turn clockwise to decrease sensitivity and

set at a higher level of relative humidity.
The timer (TM) is adjustable between 0 and

30 minutes.  Turn the trimmer clockwise to

increase the overrun time, or anti-clockwise

to decrease it.

MAINTENANCE

Before any maintenance or

cleaning operation, switch off

the fan and disconnect it from

the main power supply. The

front cover can be cleaned

with a dry cloth or soft brush

The fan must not come into

contact with any kind of liquid

or solvent.  If this should occur,

contact a qualified technician

before reassembling the fan.

NOTE: The motor does not

require lubrication as it is

maintenance free "sealed for

life" type.

DISMANTLING & RECYCLING

This product has been designed and constructed using high-quality materials and components that can be recycled or re-used. 

Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Buckinghamshire, HP12 3RH

Tel: +44 (0)1494 522333.  Fax: +44 (0)1494 522337.  Email: [email protected]  Web:  www.vectaire.co.uk