background image

2

©Vecow DVC-1000 User Manual  

GENERAL INTRODUCTION

1.3  DVC-1000 Specification

Depth Module

Technology

Active Stereoscopic

Working Distance

It may vary for calibration, scene, and lighting condition.

•  Max : 10 meters

•  Min : 0.105 meters

Resolution

1280 x 720/640 x 480/480 x 270/424 x 240

Frame Rate

Up to 60 fps

Shutter Type

Global Shutter

FoV (H x V x D)

87°±3° × 58°±1° × 95°±3° @HD Resolution

Z Accuracy

≤ 2%, up to 2 meters and 80% of FoV

Depth Sensor

OmniVision OV9282

RGB Module

Resolution

1280 x 720/640 x 480/424 x 240

Frame Rate

Up to 60 fps

FoV (H x V x D)

69.4° x 42.5° x 77°(± 3°)

Color Sensor

OmniVision OV2740

Illumina on

Type

Infrared

Wavelength

850nm

Power

Input

•  DC 12V

•  PoE

(25.5W/48V) (Compliance IEEE 802.3at PoE

+

)

Connector

•  PoE : RJ45, Lockable connector

•  DC 12V : A-coded M12

Network

LAN

10/100/1000 Ethernet, IEEE 802.3at PoE supported

Software Support

OS

•  Host : Ubuntu 16.04

•  Client : Windows 10, Ubuntu 16.04

SDK

Intel

®

 RealSense™ SDK 2.0

Mechanical & Environment

Dimensions (mm)

112.6 x 106.6 x 43

Operating Temperature 0°C to 40°C
Storage Temperature

-40°C to 70°C

Mounting

Tripod

EMC

CE, FCC

Summary of Contents for DVC-1000

Page 1: ...USER Manual USER Manual 1 1 0 Edition 20210108 Intel D435 RealSense 3D Camera DVC 1000...

Page 2: ...ii Vecow DVC 1000 User Manual Version Date Page Description Remark 1 00 2021 01 07 All Official Release 1 10 2021 01 08 1 2 6 Update Record of Revision...

Page 3: ...dio frequency energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residentia...

Page 4: ...iv Vecow DVC 1000 User Manual Part Number Description DVC 1000 DVC 1000 Intel D435 RealSense 3D Camera Order Information...

Page 5: ...fication 2 1 4 Mechanical Dimension 3 CHAPTER 2 GETTING TO KNOW YOUR DVC 1000 4 2 1 Window Version Utility 4 2 2 Optional Accessory Kit 4 2 3 I O and Indication 4 CHAPTER 3 SYSTEM SETUP 5 3 1 Installi...

Page 6: ...ut port via 12V 2A or M12 power input connector DVC 1000 is suitable for using in robotics logistics AGV AMR 3D monitoring and inspection real streaming video AI surveillance real time inspection and...

Page 7: ...OmniVision OV9282 RGB Module Resolution 1280 x 720 640 x 480 424 x 240 Frame Rate Up to 60 fps FoV H x V x D 69 4 x 42 5 x 77 3 Color Sensor OmniVision OV2740 Illumina on Type Infrared Wavelength 850...

Page 8: ...3 Vecow DVC 1000 User Manual GENERAL INTRODUCTION 1 4 Mechanical Dimension 1 2 3 4 6 7 5 8 112 6 4 43 106 6 4 42 43 0 1 69 112 6 4 43 106 6 4 20 112 6 4 43 Unit mm inch...

Page 9: ...Kit P N Description 61 1C10808 151 DVC 1000 Lockable External PoE LAN Cable 61 1C20403 001 DVC 1000 M12 to 3Pin terminal block External Power Input Cable 2 3 I O and Indication No Name Functions 1 IR...

Page 10: ...CoreTM i5 processors or above Ubuntu Linux 16 04 LTS or Microsoft Windows 10 64 bit System Internet Explorer 10 0 or equivalent or above when using Microsoft Windows 10 3 1 2 Peripheral Components Req...

Page 11: ...e If customer want to use PoE power input please use vecow utility to disable DHCP to change to static IP Camera default setting is DHCP on 3 1 3 1 By PoE Power Input 3D Camera Server Non PoE Router C...

Page 12: ...uring set up hardware environment Open DVC 1000 Utility and click search device then it will list all available devices IP Address The network IP is automatically assigned You can disable the DHCP to...

Page 13: ...ser Manual DVC 1000 Utility 4 1 2 Searching Camera IP Address Step 1 Right click the mouse Choose Login Page Step 2 Enter the default username and password and click Login Default Username admin Defau...

Page 14: ...1000 Utility Step 3 Disable the USE DHCP a dialog box will pop up then click OK Step 4 Under the same domain your IP address can be changed from 2 to 254 If IP is already exist it will show message t...

Page 15: ...e new IP and click update config When the progress bar shows100 the IP address changed successful then the device will be restart Step 6 Close the page and waiting for 30 seconds in Vecow utility sear...

Page 16: ...ssword We recommend that you change the login password immediately after you get the device Step 1 Enter to login page Click Edit Password Step 2 Set your new password and click Submit A message indic...

Page 17: ...l DVC 1000 Utility 4 1 4 Restore Factory Default Setting Step 1 If you want to restore your device to factory setting you just need to open Vecow utility and choose your device and enter to login page...

Page 18: ...ored to factory default Do you want to continue click Ok Step 3 Close the page waiting for 30 seconds in Vecow utility Search device enter to login page make sure all the items you changed before have...

Page 19: ...sure the power supply is constant throughout the process The updating process is an advanced configuration failure to comply to the instruction below may cause the camera to become unusable In that c...

Page 20: ...15 Vecow DVC 1000 User Manual DVC 1000 Utility Step 3 Select the firmware file and click Open Step 4 Click start a dialog box Do you want to update will pop up select Yes camera FW update started...

Page 21: ...FW releases The updating process takes approximately 30 minutes depending on your network condition While updating firmware make sure the power supply is constant throughout the process The updating...

Page 22: ...17 Vecow DVC 1000 User Manual DVC 1000 Utility Step 3 Select Browser and choose the new version of firmware...

Page 23: ...the device Step 6 When file transfer complete server automatically enters to update F W mode and The firmware update begins Step 7 When system firmware update successfully the system will restart it...

Page 24: ...nding on your network condition While recovery firmware make sure the power supply is constant throughout the process The recovery process is an advanced configuration failure to comply to the instruc...

Page 25: ...Do you want to recovery default system choose Yes Step 4 The recovery progress begins Step 5 When successfully recover system the system will restart it will take about 1 minute Step 6 System restart...

Page 26: ...cow DVC 1000 User Manual DVC 1000 Utility 4 1 8 Shut Down Step 1 Open VECOW utility click Search Device Step 2 Choose your device and right click mouse select Shut Down Do you want to shut down choose...

Page 27: ...w System Shut Down Step 4 You can shut down the device from the web page too IMPORTANT When the device shut down successfully if you want to use the device again you need to unplug the power cord and...

Page 28: ...want to restart choose Yes Step 3 In the lower left corner of the VECOW utility it will show System Restart Step 4 When the device restart successful wait about 30 seconds then search device again th...

Page 29: ...rt your web browser In the Search Bar type in http your IP address 8888 of your DVC 1000 camera Step 2 Entering from the webpage has the same function as VECOW utility 4 1 11 Accessing Camera Image St...

Page 30: ...C 1000 Utility Step 2 Choose Add Network Device Step 3 Type in the IP Address Use the VECOW utility to obtain the IP Address then click OK Step 4 On the left menu select Infrared1 and Infrared2 click...

Page 31: ...an see the RGB Depth IR camera now Step 6 For details on the remaining functions of Intel RealSense viewer refer to https www intel com content dam support us en documents emerging technologies intel...

Page 32: ...iguration Functions are the same as Window version include Searching Camera IP Address Change IP Address Edit password Restore factory Camera Firmware Update System Firmware Update System Firmware Rec...

Page 33: ...C 1000 Utility Step 2 Choose Add Network Device Step 3 Type in the IP Address Use the VECOW utility to obtain the IP Address then click OK Step 4 On the left menu select Infrared1 and Infrared2 click...

Page 34: ...an see the RGB Depth IR camera now Step 6 For details on the remaining functions of Intel RealSense viewer refer to https www intel com content dam support us en documents emerging technologies intel...

Page 35: ...0 3 GND 4 HW Reset 5 SYNC 6 GND 7 12V 8 GPIO_A7 1 7 6 2 3 4 8 5 Step 1 Insert a pin into the Pin 3 GND and Pin 4 HW Reset of the camera and hold 30 seconds Step 2 Re plug the camera The camera is rest...

Page 36: ...fications are subject to change without prior notice No part of this publication may be reproduced in any form or by any means electric photocopying or recording without prior authorization from the p...