6
made to either one battery or a group of batteries in a
battery bank.
Multiple same models of controllers can be installed in
parallel on the same battery bank to achieve higher
charging current.
Each controller must have its own
solar module(s).
Select the system cables according to 5A/mm
2
or less
current density in accordance with Article 690 of the
National Electrical Code, NFPA 70.
2.2 PV ARRAY REQUIREMENTS
(1) Serial connection (string) of PV modules.
As the core component of solar system, controller could
be suitable for various types of PV modules and maximize
converting solar energy into electrical energy. According
to the open circuit voltage (V
oc
) and the maximum power
point voltage (V
Mpp
) of the MPPT controller, the series
number of different types PV modules can be calculated.
The below table is for reference only.
XTRA1206/2206:
System
voltage
36cell
Voc
<
23V
48cell
Voc
<
31V
54cell
Voc
<
34V
60cell
Voc
<
38V
Max
.
Bes
t
Max. Bes
t
Max
.
Bes
t
Max
.
Best
12V
2
2
1
1
1
1
1
1
24V
2
2
-
-
-
-
-
-
System
voltage
72cell Voc
<
46V
96cell Voc
<
62V
Thin-Film
Module
Voc
>
80V
Max.
Best
Max.
Best
12V
1
1
-
-
-
24V
1
1
-
-
-