Safety information

1.  This appliance may be used by children aged eight years or above, people with

physical and mental disabilities as well as those who lack any experience, provided
that they have received detailed instructions about the functionality of the appliance
and any risks. Children must not play with the appliance. Cleaning and maintenance
must not be performed by children without proper supervision. Children under three
years of age should not be near the appliance without constant supervision.
Children between three and eight years old may only turn on/shut off the appliance
if it is located in a suitable position and they have received instructions about the
proper course of action, or are being supervised. They shall also be informed about
possible dangers. Children between three and eight years old may not connect the
device, change its settings or perform care/maintenance.

2.  The installation must be carried out by qualified and authorized personnel.
3.  The heater supply voltage and loading specifications appears on the circuit diagram

on the inside of the lid and on the ratings plate on the outside of the lid.
The circuit diagram also contains information about the thermal cut-outs.

4.  The allowed ambient temperature is  -20°C … +30°C.

The heater is made for a highest outgoing air temperature of 50°C and that is also
stated on the ratings plate.

5.  The heater must be connected to the mains using permanently installed cables.

The fixed installation must include an all-pole switch. The cable glands must be
selected such that the IP class of the heater is maintained. The protection class of
the heater is stated on the ratings plate.

6.  The heater has to be connected in such a way that it is interlocked by the built-in

thermal cut-outs, as well as by the associated fan, or the airflow that passes
through the heater
The supply voltage must not be switched on, unless the associated fan is switched
on at the same time or in advance. Furthermore, the associated fan must not be
switched off unless the heater supply voltage is switched off at the same time or
in advance.

7.  The air velocity through heaters of type -.MT.  must be at least 1.5 m/s.

The air velocity through heaters of type -.PT.  must be at least 0.5 m/s.

8.  The heater is CE marked and made in accordance with these standards:

EN 60335-1 / EN 60335-20 / EN 61000-6-1 / EN 61000-6-3 / EN 62233.

9.  The heater must not be opened when supplied with mains voltage.

10.  Hot surfaces may occur on the heater.

CAUTION: Read this manual before using the product.
Save the manual for future use.

CV ..-..-..TX  /  -..TY /  -..TC  /  -..TP

Summary of Contents for CV TC Series

Page 1: ...en CV TX CV TY CV TC CV TP Lesen Sie dieses Handbuch bevor Sie das Gerat montieren anschliessen und in Betrieb nehmen MANUEL Batterie de chauffage lectrique type IMPORTANT Veuillez lire ce manuel avan...

Page 2: ...Till ten omgivningstemperatur r 20 C 30 C V rmaren r tillverkad f r en maximal till ten utg ende lufttemperatur p 50 C 5 V rmaren skall anslutas till kraftn tet med fast f rlagd kabel En allpolig bryt...

Page 3: ...annars finns risk att luftstr mmen genom v rmaren blir oj mn med risk att verhettningsskyddet l ser ut Exempel CV 16 ger att avst ndet b r vara minst 320mm o s v 8 V rmaren f r isoleras enligt g lland...

Page 4: ...ion about the thermal cut outs 4 The allowed ambient temperature is 20 C 30 C The heater is made for a highest outgoing air temperature of 50 C and that is also stated on the ratings plate 5 The heate...

Page 5: ...sk that the airflow through the heater will be uneven which may cause tripping of the overheating cut out Example CV 16 result in a distance of at least 320mm etc 8 The heater may be insulated in acco...

Page 6: ...betr gt 20 C 30 C Das Heizger t ist f r eine spezifische maximal zul ssige Luftaustrittstemperatur von 50 C ausgelegt 5 Das Heizger t ist mit fest verlegten Kabeln an das Stromnetz anzuschlie en Die...

Page 7: ...besteht da der Luftstrom durch den Heizregister ungleichm ig wird was zum Ausl sen des berhitzungsschutzes f hren kann Beispiel CV 16 bedeutet zumindest 320 mm usw 8 Die Heizregister k nnen gem den ge...

Page 8: ...contre la surchauffe 4 La temp rature ambiante admissible doit tre comprise entre 20 C 30 C La batterie a t con ue pour une temp rature d air 50 C sortant maximale 5 La batterie doit tre raccord au r...

Page 9: ...ssion dans le flux d air circulant travers la batterie ce qui risquerait de d clencher le thermostat de surchauffe Exemple CV 16 donne que la distance doit tre d au moins 320mm etc 8 Les batteries peu...

Page 10: ...a bevat ook informatie over de bescherming tegen overver hitting 4 De toegestane omgevingstemperatuur is 20 C 30 C De verwarming is ontworpen voor een maximale toegestane afgegeven lucht temperatuur 5...

Page 11: ...keling van het element kunnen veroorzaken Voorbeeld CV 16 middelen min 320mm onz 8 De verwarmers kunnen volgens de normaal geldende regels voor het isoleren van kanaalstukken ge soleerd worden Echter...

Page 12: ...men IP luokka on luettavissa merkkikyltiss 4 Sallittu ymp rist nl mp tila on 20 C 30 C L mmitin on valmistettu erityisesti suurinta sallittua poistoilman l mp tilaa varten 50 C 5 L mmitin tulee liitt...

Page 13: ...aa kanavan halkaisija Muuten on vaarana ett l mmittimen kautta kulkeva ilmavirta on ep tasaista jolloin ylikuumenemissuoja laukeaa Esimerkiksi CV 16 merkitsee ainakin 320mm jne 8 L mmittimien erist mi...

Page 14: ...14 1 2 3 4 20 C 30 C 50 C 5 6 7 MT 1 5 PT 0 5 8 EN 60335 1 EN 60335 20 EN 61000 6 1 EN 61000 6 3 EN 62233 9 10 CV TX TY TC TP...

Page 15: ...15 1 2 3 MT PT 90 D 4 5 6 7 CV 16 320 8 9 10 11 12 40 30 30 C 50 C 1 2 24 3 1 2 3 4 CV TX TY TC TP...

Page 16: ...s Heizregister den berhitzungsschutz vom Typ Bimetall Heizregister mit im Typenschl ssel hat den berhitzungsschutz vom Typ Kapillarrohr Heizregister vom Typ hat Heizelemente mit geringerer Oberfl chen...

Page 17: ...L CV D CV PT CV MT CV TX 0 10 0 100 2 10 0 100 4 20 0 100 PWM CV TY CV TC CV TP CV L Gewoonlijk het verwarmers hebben oververhittingsbeveiligingen van het bimetalen type terwijl verwarmers met in de t...

Page 18: ...C V 1 M T Y L C V 1 M T C L 0V 0 10V 0V 2 10V 4 20mA NC NO 500mA NC NO 500mA 230V 230V 230V 230V SE GB Inkopplingsexempel T Tryckvakt E F rregling F Allpolig brytare NO Potentialfri larmkontakt normal...

Page 19: ...weise offen NC Potentialfreier Alarmkontakt normalerweise geschlossen Exemple de connexion T Capteur de pression E Verrouillage F Interrupteur multipolaire NO Contact d alarme inter normalement ouvert...

Page 20: ...V 2 M T Y L C V 2 M T C L 0V 0 10V 0V 2 10V 4 20mA NC NO 500mA NC NO 500mA SE GB Inkopplingsexempel T Tryckvakt E F rregling F Allpolig brytare NO Potentialfri larmkontakt normalt ppen NC Potentialfri...

Page 21: ...reier Alarmkontakt normalerweise geschlossen Exemple de connexion T Capteur de pression E Verrouillage F Interrupteur multipolaire NO Contact d alarme inter normalement ouvert NC Contact d alarme inte...

Page 22: ...0V 2 10V 4 20mA C V 3 M T X L C V 3 M T Y L C V 3 M T C L 0V 0 10V 0V 2 10V 4 20mA NC NO 500mA NC NO 500mA 230V 400V 3N 230V 400V 3N 400V 3N 400V 3N SE GB Inkopplingsexempel T Tryckvakt E F rregling F...

Page 23: ...halter NO Potentialfreier Alarmkontakt normalerweise offen NC Potentialfreier Alarmkontakt normalerweise geschlossen Exemple de connexion T Capteur de pression E Verrouillage F Interrupteur multipolai...

Page 24: ...mA C V 3 M T X L 2 C V 3 M T Y L 2 C V 3 M T C L 2 0V 0 10V 0V 2 10V 4 20mA NC NO 500mA NC NO 500mA 230V 230V 3 230V 230V 3 230V 3 230V 3 SE GB Inkopplingsexempel T Tryckvakt E F rregling F Allpolig b...

Page 25: ...r NO Potentialfreier Alarmkontakt normalerweise offen NC Potentialfreier Alarmkontakt normalerweise geschlossen Exemple de connexion T Capteur de pression E Verrouillage F Interrupteur multipolaire NO...

Page 26: ...ut no regulation No heating Fehlersuche Trennen Sie das Steuersignalkabel und uberbrucken Sie den Eingang Wenn das Heizregister jetzt ausgeschaltet ist liegt der Fehler im externen Regelsignal Wenn da...

Page 27: ...mte levert op 9V stuursignaal zit de fout in de controller anders ligt de fout in het externe stuursignaal Volle vermogen verwarming maar geen regeling Geen verwarming Vianetsint Irrota ohjaussignaali...

Page 28: ...nir des diff rences techniques ou des fautes d impression VEAB Heat Tech AB est habilit d velopper et ou modifier les produits et ou la brochure sans pr avis Het document kan technische afwijkingen of...

Reviews: