Configure and calibrate the fuel level sensor
1. Press the
MENU
button and select
SENSOR
CONFIG
.
2. Use
Engine 1 connector
or
Engine 2
connector
to select the connector to which the
sensor is connected.
3. Select the input connected to the sensor (i.e.
Resistive pin 8
): "Off" appears to indicate that
no sensor is linked to the input or was disabled.
4. Select
Fuel
:
Show value as
and
Calibration
parameters appear.
5. Select
Show value as
, then select the ID to be
assigned to the tank connected to the sensor.
6. Select
Calibration
to open calibration options.
7. Select
Tank volume
, to set tank capacity.
8. Select
Sensor type
, then select the sensor
type.
9. Select
Calibration
, then select the one or
three point calibration procedure (
Do 1 point
cal
/
Do 3 point cal
): calibration instructions
and the ohm value read in real-time by the
sensor
[A]
appear.
10. Empty the tank and wait for the read value to
stabilize. Then confirm by pressing
ENTER
.
11. For three point calibration, follow the on-screen
instructions.
12. Hold down the
MENU
button to return to the
data pages.
Sensor configuration
7” TFT display | Operating instruction v. 1.0 | © 2018 Continental Automotive Switzerland AG
Summary of Contents for OCEANLINK -
Page 2: ......
Page 3: ...Deutsch 5 English 45 Français 85 Español 125 Italiano 165 ...
Page 4: ......
Page 5: ...OceanLink 7 TFT Display Bedienungsanleitung v 1 0 www vdo marine com ...
Page 6: ......
Page 45: ...OceanLink 7 TFT display Operating instruction v 1 0 www vdo marine com ...
Page 46: ......
Page 85: ...OceanLink Écran 7 TFT Notice d utilisation v 1 0 www vdo marine com ...
Page 86: ......
Page 125: ...OceanLink Display 7 TFT Instrucciones para el uso v 1 0 www vdo marine com ...
Page 126: ......
Page 165: ...OceanLink Display 7 TFT Istruzioni per l uso v 1 0 www vdo marine com ...
Page 166: ......