1

User manual
ALFA 70-KLEP
Air valve control

VDH doc. 080594

Version: v1.0

Date: 24-04-2008

Software: ALFA70-KLEP

File: Do080594.WPD

Range: 0-600 sec.

* Installation.

On  the  upper  side  from  the 

ALFA  70-KLEP

  is  shown  how  the  input,  supply  and  relay  should  be

connected. A self test is startet as soon as the power supply is connected to ALFA 70-KLEP. After the
self test the normal operation will start.

* Control.

The 

ALFA 70-KLEP

 can be controlled by four push buttons on the front:

up 

- Raise the value

down

- Lower the value 

set

- Read out and change the pause time

sec.

- Read out the actual puls or pause time (Hidden key)

* Working description.

Only the active valves (see P01 till P03) are working together in the sequence 1-2-3-1-2-3 etc. (F.i.
if only valve 1 and valve 3 are active the sequence will be 1-3-1-3 etc. )
The first active valve always starts with the pulse time (adjustable with parameter P10), hereby the
corresponding dot will flash and the upper segment from the corresponding display will be on. After
the pulse time starts the pause time (can be read out with the 

SET

 key and changeable with 

UP

 and/or

DOWN

 key as long as the 

SET

 key is pushed.) The dot stays flashing while the lower  segment from

the display is on. (See drawing below.)
From the not active valves the middle horizontal segment is on.