3.1.17 System Status Pages
The projector's current operating settings may be
displayed by pressing [
] while at presentation
level. Each time [
] is pressed, one of three main
status pages is displayed. To return to presentation
level, press [
EXIT
].
Page 1
; displays general projector information and
operating settings which include identity, software
version, date and time, keypad type, scan
configuration, auto power-up setting, message
display setting, switchers (numbers) connected,
installed options, and mute setting. Operating
settings are explained in the following entries in this
section.
Page 2
; displays current input parameters. These
parameters (defined later in this section), relate
specifically to the currently selected input.
Page 3
; lists the display settings currently in use.
Note: If the current setup memory is locked or an
ASI has occurred, the display settings shown may
not be identical to those stored in the setup memory.
Note:
To view help pages pertaining to the
status pages and their contents,
press [
HELP
] during status page display.
"Time" does not update on-screen.
Serial No:
Software:
Date:
Horiz Scan:
Vert Scan:
Switchers:
Options:
Marquee
Projector No:
IR Sensor:
Remote Jack:
Auto Power-up:
Messages:
Mute:
XXXX
000
A
A
Off
On
Off
123456789
VX.X
xx/xx/xx
03:05 pm
Normal
Normal
1
CMM
ACON
VDC Display Systems
Presentation Level
Presentation Level
Page 1
Page 2
Page 3
Current Input Parameters
Channel:
Switcher:
Slot:
Recall:
ASR:
Input Module:
Horiz Freq:
Vert Freq:
Signal Type:
Sync Type:
Video Standard:
12 Computer A
1
4
01
On
Built-in RGB
75.00 kHz
72.67 Hz
RGB
Sync-On-Green
-
Contrast:
Bright:
Volume:
Color:
Tint:
Detail:
Retrace:
Sync:
Auto Clamp:
Channel:
Input:
Recall:
H Size:
V Size:
Keystone:
Side Pin:
Top Pin:
Bot Pin:
V Bow:
H C Lin:
V C Lin:
H S Lin:
V S Lin:
H Skew:
Current Display Settings
H Phase:
V Phase:
White Bal:
Focus:
T Blank:
B Blank:
L Blank:
R Blank:
H Bow:
V Skew:
(6500K)
30
50
0
50
50
25
Long
Slow
On
12 Computer A
14
01
50
50
50
50
50
50
50
50
50
50
50
50
50
50
2
50
0
0
0
0
50
50
Figure 3-4. System Status Pages