Maintenance and Upgrades
92
VideoJet 1000
When the transmission concludes, the message
transfer
complete
will be displayed and the green LED flashes. The new
firmware is now unpacked and the Flash-EPROM will be repro-
grammed.
When the green LED stops flashing, programming is complete. An
automatic reset of the device is carried out and the FTP connection
is deactivated.
)
Enter the command
quit
to terminate the FTP session.
Network check
The connection between two IP addresses can be checked by
means of the
ping
command. In this way it is possible to check
whether a unit is active on the network.
)
Open the DOS input window.
)
Enter the command
ping
followed by the address of the unit.
When the unit is found, the response:
Reply from...
, followed
by the number of bytes transmitted and the time taken for the trans-
mission in ms is displayed. If this message is not displayed, the unit
is not accessible over the network. This can be due to the following
reasons:
z
The network connection to the unit is not OK. In this case, check
out the cable connections.
z
The unit is not correctly integrated into the network. Check the IP
address, subnet mask and, if necessary, the gateway IP.
Warning!
On no account interrupt the installation of the firmware. An interrup-
tion will result in damage to the flash EPROM. This can result in the
device being no longer addressable and having to be replaced.
Summary of Contents for VideoJet 1000
Page 1: ...VideoJet 1000 Manual ...
Page 8: ...Preface 10 VideoJet 1000 ...
Page 20: ...Installation 22 VideoJet 1000 Mounting of a single unit Mounting of twin units ...
Page 28: ...Installation 30 VideoJet 1000 ...
Page 88: ...Operation 90 VideoJet 1000 ...
Page 92: ...Maintenance and Upgrades 94 VideoJet 1000 ...
Page 105: ...107 VideoJet 1000 ...