Configuration with web browser
72
VideoJet 1000
a motion alarm has been detected and to switch the light off again
at the end of the alarm.
Idle state:
Select
Open
if the relay is to operate as a normally open contact or
Closed
if it is to operate as a normally closed contact.
Operating mode:
Select the operating mode for the relay.
If, for example, a lamp is switched on by an alarm and is to remain
on when the alarm has ended, select
Bistable
. If an acoustic signal
activated by an alarm is to remain on for a period of, for example,
10 sec, select
Monostable 10
s
.
Relay follows:
Select a particular event by which the relay is to be activated as
required. The following events can activate the relay:
z
Off
: No relay triggering by events
z
Connection
: Triggering if any connection is established
z
Video Alarm
: Triggering caused by loss of the video signal
z
Input 1
: Triggering caused by an external alarm sensor
z
Remote input
: Triggering by a switching contact from a remote
location
z
Motion
: Triggering by the motion alarm
Relay name:
The relay can be assigned a name from here. The name will be
shown on the Overview page and, dependent upon configuration,
also on the Live page.
Trigger relay:
Click on the button
Relay
to manually switch the relay (e.g. for test
purposes or to operate a door opener).
Summary of Contents for VideoJet 1000
Page 1: ...VideoJet 1000 Manual ...
Page 8: ...Preface 10 VideoJet 1000 ...
Page 20: ...Installation 22 VideoJet 1000 Mounting of a single unit Mounting of twin units ...
Page 28: ...Installation 30 VideoJet 1000 ...
Page 88: ...Operation 90 VideoJet 1000 ...
Page 92: ...Maintenance and Upgrades 94 VideoJet 1000 ...
Page 105: ...107 VideoJet 1000 ...