ASSEMBLY AND INSTALLATION
INSTRUCTIONS
NOTES: 1. Before installing, consult local electrical codes for wiring and grounding requirements.
2.
READ AND SAVE THESE INSTRUCTIONS.
T0414 / T0415
180408
WARNING:
TO AVOID RISK OF ELECTRICAL SHOCK, BE SURE TO SHUT OFF
POWER WHILE INSTALLING OR SERVICING THIS FIXTURE.
Hardware Package (included):
Mounting Screw X2
#8/32X1/2 in
Mounting Screw X2
#6/32 X1/2 in
Decorative cover
Fixture Mounting Screw
Mounting Strap
Mounting Screw X2
#10/24 X1/4 in
Wire Connector X3
Page 1 / 3
Wall Mounted
Eave Mounted
Note: Fixture can be wall mounted or eave mounted.
Important to Know:
1. If you are not familiar with state and local electrical
codes, it is recommended that you consult with a
qualified electrician.
2. This fixture requires a 120 VAC, 60 Hz power
source.
3. For general safety and to avoid any possible
damage to the photocell, be sure the power is
switched "off" before adjustment.
Maximum Wattage: 44 W
Working Temperature Range: - 4
°F ~ 113°F
Features:
1. Energy saving LED fixture.
2. Photocell keeps the light OFF during daylight hours.
3. When in manual override mode, it can be switched
from 100
%
high level to low level brightness.