Installation Steps

Turn off the power at fuse or circuit box.

Turn on the power at  fuse or circuit box.

sensor

Adjusting the Sensor Head:

1. Aim sensor head toward desired detection area, maintaining a 

    5° - 40° downward angle to allow moisture to drain.

    Note: Make sure sensor head is positioned with controls facing 

    toward the ground.

2. You can move the sensor head up and down to change the coverage 

    area. (See Fig. 1) 

    

Note: Range set too high may increase false triggering.

 

    (See Fig. 2 and Fig. 3 on Page 3)

 

Fig. 1

1. Install the mounting strap to the outlet box with the stamped word “FRONT” facing away from the outlet box, using 

    two mounting screws that best fit the outlet box. Back plate should sit flush against wall surface when secured.

    (Choose one matching pair of suitable mounting screws from the 3 pairs provided)

2. Fixture wires thread through gasket, then attach the gasket into back plate.

3. Pull out the source wires from the outlet box. Make wire connections using wire nuts as follows:

     ---Connect the black wire from the fixture to the “hot” wire from the power source. (usually black)

     ---Connect the white wire from the fixture to the neutral wire from the power source. (usually white)

     ---Connect the grounding wire from the fixture to the grounding wire from the power source. (usually green / 

         yellow insulation)

     Carefully tuck the wires back into the outlet box.

4. Attach the back plate of the light fixture to the mounting strap, secure it with the fixture mounting screw.

5. Push the decorative cover firmly into the fixture mounting screw hole on the light.

6. Align the three slots in the decorative shell with the light head pins. Push the shell in and then twist clockwise to 

    lock. Repeat for the other shell. 

7. Install bulbs (not included). See relamping label at socket area or packaging for maximum allowed wattage.

8. With silicone caulking compound, caulk completely around where the back plate meets the wall surface.

  CAUTION: Be sure to caulk completely where the back plate meets the wall surface to prevent water from 

    seeping into the outlet box.

Sensor

Mounting Strap 

Outlet Box

Wire Nut

Back Plate

Mounting Screw

Fixture Mounting Screw 

Light Head

FRONT

Decorative Cover 

Decorative Shell

Gasket

RAP 38 Bulb Max.150W

(not included)

150623

Reviews: