Vauconsant A62608 User Manual Download Page 1

   

                                     

USER MANUAL

 

Rue Charles Hermite 

 

Z.I des Sables – BP 59

  

 

54110 Dombasle-sur-Meurthe 

 

France 

 

Tel: + 33 (0)3 83 45 82 82 

 

Fax: +33 (0)3 83 45 82 93 

 

www.vauconsant.com

 

 

Public limited company with executive 
and supervisory board capitalised at €1,000,000 
Chèques Postaux account: 2145 J Nancy 
NAF 28.93.Z 
RCS (French business registration n°) Nancy B 757.804.042 
EU VAT number:  FR 52 757 804 042

 

 

 
 

E

E

X

X

I

I

G

G

E

E

N

N

C

C

E

E

 

 

 

 

T

T

O

O

U

U

G

G

H

H

E

E

N

N

E

E

D

D

 

 

G

G

L

L

A

A

S

S

S

S

 

 

T

T

O

O

P

P

 

 

 

 

F

F

R

R

E

E

E

E

 

 

S

S

P

P

A

A

C

C

E

E

 

 

B

B

E

E

L

L

O

O

W

W

 

 

W

W

I

I

T

T

H

H

 

 

 

 

H

H

E

E

A

A

T

T

I

I

N

N

G

G

 

 

D

D

I

I

S

S

P

P

L

L

A

A

Y

Y

 

 

O

O

P

P

T

T

I

I

O

O

N

N

 

 

 

 
 
 

 

 

 
 
 

 

 
 
 
 
 
 

 
 
 
 
 
 
 

A62608 (2GN) : 930 x 820 x 900 (+430) mm

 

A62613 (3GN) : 1380 x 820 x 900 (+430) mm 
A62615 (4GN) : 1580 x 820 x 900 (+430) mm 
A62619 (5GN) : 1930 x 820 x 900 (+430) mm 
A62622 (6GN) : 2280 x 820 x 900 (+430) mm 
 

Summary of Contents for A62608

Page 1: ...y NAF 28 93 Z RCS French business registration n Nancy B 757 804 042 EU VAT number FR 52 757 804 042 E EX XI IG GE EN NC CE E T TO OU UG GH HE EN NE ED D G GL LA AS SS S T TO OP P F FR RE EE E S SP PA AC CE E B BE EL LO OW W W WI IT TH H H HE EA AT TI IN NG G D DI IS SP PL LA AY Y O OP PT TI IO ON N A62608 2GN 930 x 820 x 900 430 mm A62613 3GN 1380 x 820 x 900 430 mm A62615 4GN 1580 x 820 x 900 43...

Page 2: ...reserved A622xx E633xx rev0 ENG 2 12 2010 2 Manual to be read and kept Contents Introduction 3 Installation Controls 4 Commissioning Use 6 Cleaning Diagnostic 7 Maintenance 8 Electric diagrams 9 Spare parts Technical support 11 Warranty 12 ...

Page 3: ...at a temperature above 63 C according to hygiene requirements for 90 minutes using GN1 1 65 mm deep gastronorme trays The temperature of the food provided should be between 70 C and 80 C These units comply with applicable EC norms and should be installed and used following the instructions in this manual to ensure good performance and to be covered by the warranty ...

Page 4: ... mains in the case of a mobile unit The line should be protected by a differential circuit breaker on the general electricity panel o Installation of a breath shield heating display option 1 Dismantle the upper glass brackets with a six sided spanner Ø 2 5 2 Stick the black non slip adhesive patches in the specified markings on the part of the bracket in contact with the breath shield 3 Install th...

Page 5: ...rights reserved A622xx E633xx rev0 ENG 2 12 2010 5 Overhang adjustment The unit s overhangs should be positioned as shown below The unit should be level Assembly dismantling of facing Mounting with spanner rack supply Step 1 Step 2 ...

Page 6: ...n This position maintains the temperature of food above 63 C which is the minimum temperature defined by the hygiene department To maintain this temperature it is indispensable to heat food to a temperature between 70 C and 80 C GN A A gastronorme trays should be 65 mm deep The temperature of the heating tops may be set from 40 C to 110 C Heating display option Press the switch Position 0 Off Posi...

Page 7: ...medies No electricity supply Check the general circuit breaker Burnt fuse Check the fuse in the electric cabling Orange light off No heat Faulty supply Check the supply cable Defective toughened glass plate Replace the toughened glass plate Orange light on No heat Cable disconnected or cut Check and test electricity input to the toughened glass plates Halogen bulb burnt Replace the bulb with one o...

Page 8: ...veted lid under the plate Halogen lighting Halogen connections are located above the halogen support To access remove the 2 mounting screws linking it to the beam Electric cabling Electric cabling is fixed behind the built in control panel To access this remove the 4 screws holding the panel The installer should check electric connections when commissioning the unit then once a year Any maintenanc...

Page 9: ... A62615 A62619 A62622 Number of GN2 1 600 W toughened glass plates 1 1 2 2 3 Number of GN1 1 300 W toughened glass plates 0 1 0 1 0 Heating top Total power of the top W 600 900 1 200 1 500 1 800 Unit s total power W 600 900 1 200 1 500 1 800 gG A fuse caliber 4 4 6 8 8 Dd Energy doser Rv Heating toughened glass Q Fuse holder Vv Light indicating toughened glass warming ...

Page 10: ...300 W toughened glass plates 0 1 0 1 0 Heating top Total power of the top W 600 900 1 200 1 500 1 800 Number of halogen lamps 200W 2 3 4 5 6 Heating display Total power of the heating display W 400 600 800 1 000 1 200 Unit s total power W 1 000 1 500 2 000 2 500 3 000 gG A fuse caliber 6 8 10 12 16 Dd Energy doser Rv Heating toughened glass Lh Halogen lamp Sh Halogen lighting on off Q Fuse holder ...

Page 11: ...eating plate X X X X X 06 0927 GN1 1 530x325mm 300W toughened glass heating plate X X 07 2210 Black silicone joint to stick the heating plates X X X X X Electric equipment 06 1070 Black PVC button 43 mm X X X X X 06 1505 Energy doser X X X X X 06 1600 Orange light X X X X X Halogen heating lighting 06 0617 Aluminium reflector on halogen lighting X X X X X 06 0622 Halogen lamp 200 W X X X X X 06 06...

Page 12: ...used by defects or poor maintenance of equipment or damage caused by knocks or improper use Any warranty also excludes incidents caused by fortuitous events or force majeure unidentified causes or causes by the buyer s actions of any form whatsoever improper location faults linked to use operation maintenance not in accordance with this manual unqualified staff etc modification of the equipment re...

Reviews: