Series 642
OPERATION
605403ED
Edition 2017-11-24
65/94
5.6
Display information
There is a 4 digit display located on
the panel. It displays configuration,
status and position information. For
details see following tables.
5.6.1
Power up
Description
Digit 1
Digit 2
Digit 3
Digit 4
●
Power On:
All dots are illuminated
#
#
#
#
●
1
st
information for about 3s:
Firmware generation
[e.g. 1G..]
1
G
●
2
st
information for about 3s:
Firmware version and
firmware revision [e.g.
00 05]
0
0
0
5
●
3
nd
information for about 3s:
Valve type [e.g. .642]
6
1
2
●
4
nd
information for about 3s:
Controller configuration
In case D999 is displayed,
motor interlock is active. Refer
to «Safety mode» for details.
1
= Logic
interface
0
= basic
1
= with SPS
1)
2
= with PFO
2)
3
= with SPS
1)
and PFO
2)
1
= 1 sensor
version
2
= 2 sensor
version
SYNC indicates that powerup
synchronization is running.
S
Y
N
C
1)
SPS = optional ±15 VDC Sensor Power Supply module,
2)
PFO = Power Failure Option
Display
1 2 3 4