INSTALLATION
Series 264
10/26
Edition 2013-10-09
603392EA
4.2
Installation into the system
WARNING
Movable parts
Human body parts may get jammed and severely injured.
Do not connect or supply electrical power and compressed air before the
product is completely mounted in the system.
CAUTION
Hot surfaces
Risk of burning when touching hot surfaces.
Take safety measures in order that the valve cannot be touched during
operation. Ensure air circulation of coil.
NOTICE
Contamination
Product may get contaminated.
Always wear cleanroom gloves when handling the product.
NOTICE
Inappropriate tools
Sealing surfaces may get damaged.
Do not use sharp-edged tools.
1. Check and carefully clean sealing surfaces of valve flanges and counter flanges.
2. Install valve with connection components appropriate for ISO-K flanges according the
specification of «Table 4-1» on page 11 into account.