Safety and Environmental Information
or recycle most end-of-life materials in a safe way. The
crossed-bin symbol
invites you to use these recycling
systems.
Further information on collection, reuse and recycling is available from your local or regional refuse
administration center.
For further information on the IDENTIKEY Appliance and the environment, please contact your supplier.
Avoid dropping the IDENTIKEY Appliance
: hold the appliance firmly by its main casing. Do
not
lift the
device by the silver colored 'D' shapes at the front of the appliance. These are the chassis handles and are
only intended for sliding the IDENTIKEY Appliance in and out of the chassis rails (see
).
2.4
Temperature, Power and Humidity
VASCO recommends installing the IDENTIKEY Appliance in a server room with air conditioning and UPS
(Uninterrupted Power Supply). If the equipment is built into a server cupboard, make sure that there is sufficient
ventilation. Environmental requirements are:
Operating Temperature Range: 10 to 35 degrees Celsius (50 to 95 degrees Fahrenheit)
Non-Operating Temperature Range: -40 to +70 degrees Celsius (-40 to 158 degrees Fahrenheit)
Humidity Range: 8% to 90% non-condensing
Non-Operating Humidity Range: 5% to 95% non-condensing
Power Supply: Thermal control 260 W AC power supply with PFC [24-pin, 4-pin=12V, (2) 4-pin]
AC Voltage: 100-240 V, 60-50 Hz, 4 Amp Max
DC Output: 5V + 3.3V <= 140 W
+5V: 25.0 Amp
+5V standby: 2.0 Amp
+12V: 18.0 Amp
-12V: 1.0 Amp
+3.3V: 15.0 Amp
2.5
Dimensions
Table 1: IDENTIKEY Appliance Dimensions
AG-3XXX
AG-5XXX
AG-7XXX
Height
1.7'' (43mm)
1.7'' (43mm)
3.5'' (89mm)
Width
16.8'' (426mm)
16.8'' (426mm)
17.2'' (437mm)
Depth
10'' (253mm)
14'' (356mm)
17.7'' (450mm)
IDENTIKEY Appliance Installation and Maintenance
11