OPERATION AND MAINTENANCE MANUAL
ID MOTORS
PAGE: 45
CODE: CTT52 EDITION: 03 RELEASE: APRIL 2019
Subject to technical changes without prior notice
The earth protection conductor must be connected to the terminal indicated for said function.
5.2.4
Connections for the fan, thermal sensors and accessories
The fan motor cables must be connected in accordance with the specified voltage or that given on the fan motor nameplate (ID
motors) or the main motor nameplate (on the IDX motors).
To connect the thermal sensors, use terminals of 1.5 mm
2
on the tip and connect them to the corresponding nylon strip.
Where possible, connect the encoder or dynamo as shown in the schematic on the interior of the terminal box.
Where necessary, connect the brake cables in accordance with the voltage specified on the motor specifications plate. The
connection on the ID motors is made using a nylon strip attached to the brake body; on the IDX, there is a connector on the top of
the fan housing.
DANGER
A poor earth connection involves a severe risk of electrocution through accidental contact with the motor surface.