6. Replace the lamp
1. Disconnect the fixture from the power supply system and allow the capacitor to discharge for 1
min and cool down the fixture.
2. Remove the screw on the sides and open the front glass cover.
3. Disconnect the lamp wires at the screw terminal.
4. Lift the old lamp out of the holder.
5. Lay the new lamp on the front glass above the lamp clips, with the end with two wires on the
side close to the main cable.
6. Connect the two wires with the white isolation to the outside terminal on each end. Connect
the wire with clear insulation to the inside terminal on the closest to the main cables. Push the
isolation for each wire as far as will go into the block.
7. Press the lamp into the clips.