12
Värmebaronen MP4 G2 / MP6 G2
Menu - Service Level
Service level, rows 11-19, alternate between displaying row number window and parameter value.
area
std
11.
1
Display of the number of power steps connected.
MP4 / MP6 G2 connected:
• 230V~
: a power step, shows "2" when power is connected.
• 400V 2N~
: a power step, shows "2" when power is connected.
• 400V 2N~ + N - X jumper : two power steps, showing "1" and "2" respectively for connected power steps.
• 400V 3N~
: two power steps, display "1" and "2" respectively for connected power steps.
12.
0
Selection of the temperature regulation function.
Fixed boiler temperature.
0: fixed
temperature
12.
1
UTK function, temperature regulation with the influence of outdoor temperature and
possibly room temperature.
1: UTK
1
13. 10
UTK min-limit, minimum boiler temperature/flow temperature.
The value is displayed when the UTK function is activated in the "Service Level"
menu, row 12.
If there are no special requirements, this should be set as low as possible.
10 – 50
10
13. --
UTK function not selected, boiler regulates for fixed boiler temperature.
14. 20
UTK max-limit, maximum boiler temperature/flow temperature.
The value is displayed when the UTK function is activated in the "Service Level"
menu, row 12.
The maximum permitted flow temperature is selected so that it is not lower than
the temperature that the heating curve selected gives on the “coldest day”.
20 – 60
40
14. --
The boiler regulates for a fixed boiler temperature/flow temperature.
15.
0
15.
1
UTK, alternative temperature, display of the status of the input.
Digital input that activates the function when it is closed. Can be used for night-
time reduction, holiday mode or similar.
If different temperatures are desired at different times of the day, a timer can be
connected to
the boiler, see Electrical installation; Alternative temperatures.
To adjust the temperature, down/up - see “Service level” menu row 16.
Displays the value if UTK is activated in "Service Level" menu row 12.
0 = not active
1 = active
15.
0
15.
1
Blocking when fixed temperature regulation is selected.
Fixed temperature regulation - power connection allowed.
Fixed temperature regulation - blocking.
0 = operation
1 = blocking
Delivery setting