Variotech LUPO 24V Operating	 Instruction Download Page 1

 

Manual LUPO1S24V47.doc / 12.03.2012  

 

 

 

 

 

 

 

            

page 1 of 4

 

Variotech

      load weighing unit Pluto 

 

Number: 201203 / date: 12.03.2012 
Software version: V47 

 
 
 
 
 
 
 
 
 

LIST OF CONTENTS 

1

 

DESCRIPTION 1

 

2

 

SPECIFICATIONS 1

 

3

 

TECHNICAL CHARACTERISTICS 

1

 

4

 

ELECTRICAL CONNECTION 

1

 

5

 

FRONT PANEL 

2

 

6

 

OPERATION 2

 

7

 

ADDITIONAL SETTINGS 

3

 

8

 

FUNCTIONAL TEST 

3

 

9

 

FAULT DIAGNOSTICS 

4

 

10

 

MAINTENANCE AND WARRANTY: 

4

 

11

 

OTHER LOAD WEIGHING UNITS 

4

 

12

 

SALES DEPARTMENT AND CUSTOMER SERVICE 

4

 

 

1 Description 

 

The load weighing unit LUPO with an external load sensor controls and shows the load of a lift car and it meets the 
requirements of EN81 (14.2.5.1 and 14.2.5.2). The unit has three floating relays for switching minimum load, full load and over 
load. LUPO can be used for all types of lifts.  

 

The installation and the setting-up operation of LUPO are very simple and need only short time.  
No additional measuring tool is needed. The unit is state-of-the-art with improved and up-to-date electronic.  

 

The electronic is built in a plastic housing (IP54). 

 

The cable for the load sensor and the connection cable must be mechanical fixed and protected.  

2 Specifications 

 

The load weighing unit LUPO is compact and a combination of electronic and (external) load sensor. 

 

The big advantage of LUPO is the simple and fast setting. 

 

ADVICE:

 The setting of the unit should be done after the safety gear test. 

 

Connection cable is used for the power supply and the electrical connection to the lift control. (not scope of supply) 

 

The proper operation can be influenced by: 
- Electromagnetic 

influences: door motor, contactors, … 

3 Technical 

characteristics 

electrical data: 

power supply: 

24V DC  +/- 15%;  0,1VA 

relay output for full load; 

250V AC, 150 V DC, 1A,  

relay output for overload; 

250V AC, 150 V DC, 1A,  

relay output for minimum load;  

250V AC, 150 V DC, 1A,  

Display for settings 

7- segment Display (3 digits) 

programming / setting 

push buttons (Menu, Plus, Minus, OK) 

display of thresholds  

LED (red), lights if above thresholds 

 
mechanical data: 

dimensions  

135mmx170mmx85mm (wxhxd) 

load 0,5 

kg 

 

OPERATING INSTRUCTION FOR 

LOAD WEIGHING CONTROL

 

LUPO 24V 

Reviews: