10.2 Climatic and environmental requirements
Operation: +05 °C ... +40 °C
Environment:
▪
not for use with flammable media or in an
explosive environment
▪
not for use in moist and wet areas
▪
not for use in dirty or dusty environments
▪
not for use in aggressive environments (for
example, atmosphere containing salt,
corrosive vapors, etc.)
Table 10.2:
Climatic and environmental requirements
Electrical and software-technical requirements
Power supply: 24V DC 2A and 48V DC 2A
Switch on duration (ED): < 50%
Connections: M12 cable - control line between VarioShaker
and control box
Control: Separate control box in control cabinet
Ethernet (TCP/IP) For the initial configuration and optionally on
customer request for actuation of the control
Software: WebGUI through standard web browser (Google
Chrome, Apple Safari)
Table 10.3:
Climatic and environmental requirements
10.3 Material and component properties
10.3.1 Maximum part size
The manufacturer recommends a part size from 0.5 to approx. 50mm. The
maximum part size, however, is based on the optimal part number for the
respective process. This part number must be determined empirically dependent
on the orientation behavior and the tapping process.
The most stable process is normally achieved when the tapping area is covered
with components up to 2/3.
10.3.2 Maximum part weight
A general specification about the maximum part weight cannot be provided. The
weight threshold is dependent on the component geometry and the material. If the
components are too heavy, they cannot be re-oriented in a process-safe manner.
Components should always be examined for suitability in advance.