Varilight V-Pro IR Instructions Download Page 1

INSTRUCTIONS FOR VARILIGHT  
V-PRO IR DIMMERSWITCHES 
 

OVERVIEW  

Thank  you  for  choosing  a  VARILIGHT  V-Pro  IR  intelligent 
programmable  touch/remote  control  dimmerswitch.  Use  only  on  an 
electricity supply of 200-250 volts AC. 
IMPORTANT:  Read  ALL  sections  below  before  installing  this 
dimmerswitch. 
V-Pro  IR  dimmers  are  set  to  run  in  trailing-edge  Mode  1  by  default. 
This  versatile  mode  is  suitable  for  most  dimmable  LEDs.  It  is  also 
gentler  on  the  load.  Some  types  of  dimmable  LED  perform  best  with 
leading-edge  control.  This  dimmer  can  easily  be  set  to  run  in  leading 
edge Mode 2 by following the instructions under “Programming”. Mode 
3 is suitable for some external LED drivers. 
The  V-Pro  IR  master  dimmer  is  suitable  for  1-way  circuits.  For  2-way 
(or multi-way) circuits, use a V-Pro IR master dimmer with one or more 
dimming  slave  units.  V-Pro  IR  touch/remote  dimmers  cannot  be  used 
in  conjunction  with  conventional  switches  in  a  2-way  circuit.  Use  only 
on an electricity supply of 216-253V~. 
Dimming slaves are touch control only. Remote control is only possible 
for the master unit. 
This product complies with European Safety Regulations (IEC 669-2-
1  or  BSEN60669-2-1)  when  used  in  lighting  circuits  containing  MCBs 
(miniature  circuit  breakers).  These  can  be  rated  at  6A,  10A  or  16A 
(preferably  6A  for  lighting  circuits).  Your  guarantee  is  not  affected  if 
you have an older lighting circuit protected by fuse wire links. 
 

LOADING 

Maximum  loads  for  V-Pro  IR  dimmerswitches  (please  see 
www.varilight.co.uk for latest loading advice); 
Always observe the recommended maximum load. 

Dimmer 

Series 

Lighting  
Load 

V-Pro IR 

1 Gang 

Max. Load 

V-Pro IR 

2 Gang 

Max. Load 

Per Gang 

V-Pro IR 

3 Gang 

Max. Load 

Per Gang 

V-Pro IR 

4 Gang 

Max. Load 

Per Gang 

Dimmable Mains 
LEDs  

1 to 10 Dimmable LEDs (max. 100W) 

Check your LED lamps are suitable for use with 

dimmers that have a standby mode. A load 

regulator may be required, e.g. Varilight Glowfix

 

Low Voltage LED 
[USE DEFAULT 
MODE 1 ONLY] 

100W 

100W 

100W 

100W 

Mains 
Incandescent 

350W 

200W 

250W 

200W 

Mains Halogen 

300W 

150W 

200W 

150W 

Low Voltage 
Halogen 

300W 

150W 

200W 

150W 

Maximum of 10 lamps for GLS and Halogen loads 

Dimmable CFL 

For 1 to 8 Digiflux CFLs 

Use MODE 3: Digiflux Mode [see “Programming”] 

Visit www.varilight.co.uk/digiflux for latest advice 

 

THIS SWITCH IS SUITABLE FOR 

 

Most dimmable LEDs 

 

Mains voltage incandescent GLS or candle-shaped bulbs; 

 

GU10 or similar mains halogen bulbs 

 

Dimmable electronic low voltage transformers 

 

Dimmable CFLs (Use Mode 3) 

 
THIS SWITCH IS NOT SUITABLE FOR: 

 

Non-dimmable fluorescent bulbs and tubes; 

 

Wire-wound or toroidal transformers;  

 

Electric motors 

 
OVERLOAD PROTECTION: 
This dimmerswitch is protected against overload. If an overload occurs 
it  will  automatically  turn  off  until  the  overload  is  removed  and  the 
dimmerswitch  is  switched  off  and  then  switched  back  on  again. 
However,  if  the  dimmerswitch  receives  a  total  short-circuit  it  may  be 
damaged beyond repair. 
 

 
 
 
 
 

 

LOADING (Continued) 

TRANSFORMERS  
Use only with quality dimmable electronic transformers. For optimum 
performance choose VARILIGHT transformers*.  
To  calculate  load,  add  the  VA  ratings  of  the  transformers  (not  the 
wattage  of  the  bulbs).    Choose  transformers  with  a  maximum  rating 
close to their lamp load (eg. Use a 50VA, 60VA or 70VA transformer 
to control a 50W low voltage bulb).N.B. Certain transformers may not 
behave  according  to  their  power  rating  when  used  with  a 
dimmer
. An overload will result in the dimmer turning itself off. If this 
happens,  change  your  transformer(s)  (VARILIGHT  transformer(s) 
recommended);  or  remove  one  (or  some)  transformer(s)  from  the 
circuit; or choose a higher rated dimmer instead. 
If a transformer appears as a highly inductive load, e.g. Wire-wound 
or  toroidal  transformers,  the  dimmer  will  not  work.  To  protect  itself  it 
will turn off within 1 second. 
 
ADVICE ON CHANGING LIGHT BULBS 
Always turn off the mains power when light bulbs controlled by your V-
Pro IR dimmers are replaced. If you change the type of light bulb then 
restore factory settings as described under “Programming”. 

 

FREQUENTLY ASKED QUESTIONS 

For FAQs, please visit: www.varilight.co.uk/faqs  
 

GUARANTEE 

In  case  of  any  defect,  return  the  dimmer  to  our  service  department. 
Varilight undertakes to repair or replace, at its discretion, goods which 
have  become  defective  within  12  months  of  purchase,  solely  as  a 
result of faulty materials and workmanship, provided that:-  
a)  The  unit  has  been  correctly  fitted  according  to  the  instructions  and 
has  not  been  used  with  an  incompatible  load,  fluorescent  tubes,  or 
overloaded beyond its rating, and has only been used on a 200-250V 
a.c. power supply.  
b) The dimmer module has not been tampered with or taken apart.  
c)  The  unit  is  securely  packed  and  safely  returned  to  Service 
Department, Carylls Lea, Faygate, Horsham, West Sussex, RH12 4SJ  
(Tel.  (01293)  851584)  together  with  a  letter  stating  the  guarantee 
registration  number  below,  the  date  and  place  of  purchase,  the  type 
and  wattage  of  the  lighting  or  other  load  being  controlled  and  the 
details  of  the  fault.  This  guarantee  states  Varilight’s  entire  liability, 
which  does  not  extend  to  cover  consequential  loss  or  damage  or 
installation costs arising from a defective product. The guarantee does 
not  apply  to  problems  arising  from  any  incompatibility  between  your 
lamps  and  the  dimmer  switch.  This  guarantee  does  not  in  any  way 
affect  the  statutory  rights  of  the  purchaser  and  is  offered  so  that  you 
may have the benefit of our technical facilities.  
GUARANTEE REGISTRATION NUMBER IJ002. 
 
 
 
 
 
 

 

 

 

 

 

www.varilight.co.uk 

IJ_I

 

Please record the batch number printed on the side 
of the plastic moulding on the rear of the product. This 
will assist us in providing any technical support you 
may require. 

Reg. IJ002 

BATCH NO: 

INSTALLERS – Please leave these instructions with your customer 
for future reference. 

WARNING:  Do  not  apply  products  with  metal  faceplates  directly 
to freshly plastered or damp surfaces as product may tarnish. If in 
doubt,  use  polythene  as  a  temporary  gasket  to  protect  the 
product. Do not use masking tape on metal faceplates.  

 

Summary of Contents for V-Pro IR

Page 1: ...ond repair LOADING Continued TRANSFORMERS Use only with quality dimmable electronic transformers For optimum performance choose VARILIGHT transformers To calculate load add the VA ratings of the transformers not the wattage of the bulbs Choose transformers with a maximum rating close to their lamp load eg Use a 50VA 60VA or 70VA transformer to control a 50W low voltage bulb N B Certain transformer...

Page 2: ... AND MULTI WAY CIRCUITS In 1 way lighting circuits the light s are controlled by one switch This dimmer should replace that switch The live wire must be connected to the terminal marked LIVE and the load wire to the terminal marked LOAD To fit 2 3 or 4 gang dimmers treat each group of terminals at the back of the unit as a separate dimmer You may also need a short length of wire to connect togethe...

Page 3: ...ond repair LOADING Continued TRANSFORMERS Use only with quality dimmable electronic transformers For optimum performance choose VARILIGHT transformers To calculate load add the VA ratings of the transformers not the wattage of the bulbs Choose transformers with a maximum rating close to their lamp load eg Use a 50VA 60VA or 70VA transformer to control a 50W low voltage bulb N B Certain transformer...

Page 4: ... AND MULTI WAY CIRCUITS In 1 way lighting circuits the light s are controlled by one switch This dimmer should replace that switch The live wire must be connected to the terminal marked LIVE and the load wire to the terminal marked LOAD To fit 2 3 or 4 gang dimmers treat each group of terminals at the back of the unit as a separate dimmer You may also need a short length of wire to connect togethe...

Reviews: