Varilight V-PLUS IR Instructions Download Page 1

INSTRUCTIONS FOR VARILIGHT  
V-PLUS IR DIMMERSWITCHES 

 
OVERVIEW 

Thank  you  for  choosing  a  VARILIGHT  V-Plus  series 
dimmerswitch,  designed  for  all  incandescent  lighting  circuits 
(including  mains  or  low  voltage  halogen).  Use  only  on  an 
electricity supply of 200-250 volts AC.  
V-Plus  dimmers  are  recommended  for  use  with  halogen  loads. 
The  soft-start  feature  gently  increases  the  power  supplied  to  a 
lamp  when  the  dimmer  is  first  turned  on,  allowing  the  lamp  to 
warm  up  gradually,  reducing  failures  caused  by  stress  on 
halogen lamps when they are switched on. 
IMPORTANT:  Read  ALL  sections  below  before  installing  this 
dimmerswitch. 
This  dimmer  is  suitable  for  1-way  circuits.  For  2-way  (or  Multi-
Way  switching)  use  this  Master  Unit  with  any  number  of 
VARILIGHT  Dimming  Slaves.  N.B.  This  unit  cannot  be  used  in 
conjunction with conventional switches in a 2-way circuit. 
This 

dimmerswitch 

complies 

with 

European 

Safety 

Regulations  (IEC  669-2-1  or  BSEN  60669-2-1)  when  used  in 
lighting  circuits  containing  MCBs  (minature  circuit  breakers). 
These can be rated at 6A, 10A or 16A (preferably 6A for lighting 
circuits).  Your  guarantee  is  not  affected  if  you  have  an  older 
lighting circuit protected by fuse wire links. 

 

LOADING 

Maximum loads for V-Plus IR dimmerswitches; 

Dimmer 

Series 

 

Lighting  
Type 

V-Plus IR 

1-Gang 

V-Plus IR 

2-Gang 

Per Gang 

V-Plus IR 

3-Gang  

Per Gang 

V-Plus IR 

4-Gang  

Per Gang 

Incandescent 

As per 

loading on 

dimmer 

As per 

loading on 

dimmer 

As per 

loading on 

dimmer 

As per 

loading on 

dimmer 

Main Halogen 

Low Voltage 
Halogen 

Eco Halogen 

 
THIS SWITCH IS SUITABLE FOR 

 Mains voltage GLS or candle bulbs 

 Good  quality  dimmable  electronic  low  voltage  transformers 

(including 

those 

requiring 

trailing-edge 

control) 

[see 

“Transformers"]  

 GU10 or similar HiSpot mains halogen bulbs 

 
THIS SWITCH IS NOT SUITABLE FOR 

  Fluorescent bulbs and tubes 

  Wire-wound or toroidal transformers  

  Electric motors 

 
TRANSFORMERS 
Use  only  on  quality  dimmable  Electronic  Transformers.  For 
optimum performance choose VARILIGHT Transformers*.  
To  calculate  load,  add  the  VA  ratings  of  the  transformers  (not 
the wattage of the bulbs). Choose transformers with a maximum 
rating close to their lamp load (e.g. Use a 50VA, 60VA or 70VA 
transformer to control a 50W low voltage bulb).  
N.B.  Certain  transformers  may  not  behave  according  to  their 
power rating when used with a dimmer. An overload will result in 
the safety features of this dimmer turning down the brightness. If 
so,  change  your  transformer(s)  (VARILIGHT  transformer(s) 
recommended);  or  remove  one  (or  some)  transformer(s)  from 
the circuit; or choose a higher rated dimmer instead.  
* If a transformer  appears as  a  highly inductive load, e.g. Wire-
wound  or  toroidal  transformers,  the  dimmer  will  not  work.  To 
protect itself it will turn off within 1 second. The dimmer will allow 
this  to  happen  3  times  before  locking  further  use  until  it  is 
disconnected and reconnected to the mains electricity. 

 
 
 

 
 
 
 

 

LOADING (Continued) 

OVERLOADING AND UNDERLOADING 
Dimmers  must  not  be  overloaded  or  underloaded.  Check  the 
label on the back of your dimmerswitch for the maximum ratings 
of  each  module  and  adjust  this  if  necessary  according  to  the 
load  type  (see  above).  The  minimum  loads  for  each  are  also 
shown on the label. 
 
OVERLOAD PROTECTION 
As  a  safety  feature,  this  dimmer  is  protected  against  overload 
and  overheating.  (NB.  Some  types  of  bulb  can  draw  more 
current  as  they  age  and  overload  the  dimmer).  If  the  dimmer 
becomes  too  hot,  it  will  attempt  to  handle  the  overload  by 
reducing the brightness of the lamps. If it is unable to do so the 
dimmer  will  automatically  turn  the  lights  off  until the  overload  is 
removed and the dimmer is switched off and then switched back 
on again. 

 

FREQUENTLY ASKED QUESTIONS 

For FAQs, please visit: www.varilight.co.uk/faqs 

 

GUARANTEE 

In  case  of  any  defect,  return  the  dimmer  to  our  service 
department.  Varilight  undertakes  to  repair  or  replace,  at  its 
discretion,  goods  which  have  become  defective  within  12 
months  of  purchase,  solely  as  a  result  of  faulty  materials  and 
workmanship, provided that:- 
a) The unit has been correctly fitted according to the instructions 
and  has  not  been  used  with  an  incompatible  load,  fluorescent 
tubes, or overloaded beyond its rating, and has only  been used 
on a 200-250V a.c. power supply. 
b)  The  dimmer  module  has  not  been  tampered  with  or  taken 
apart.  However,  for  your  convenience,  it  is  perfectly  in  order  to 
remove  a  faulty  dimmer  module  from  multi-gang  dimmers  by 
pulling off the knob and unscrewing the nut under the knob. You 
will  then  still  have  the  remaining  modules  working  whilst  we 
service your faulty module. 
c) The unit is securely packed and safely returned to:- 
Service  Department,  Carylls  Lea,  Faygate,  Horsham,  West 
Sussex, RH12 4SJ 
(Tel. (01293) 851584) together  with a letter 
stating  the  guarantee  registration  number  below,  the  date  and 
place  of  purchase, the  type and  wattage of the  lighting  or other 
load being controlled and the details of the fault.  
This  guarantee  states  Varilight’s  entire  liability,  which  does  not 
extend  to  cover  consequential  loss  or  damage  or  installation 
costs  arising  from  a  defective  product.  The  guarantee  does  not 
apply to problems arising from any incompatibility between your 
lamps  and  the  dimmer  switch.  This  guarantee  does  not  in  any 
way affect 
the  statutory  rights  of  the  purchaser  and  is  offered  so  that  you 
may have the benefit of our technical facilities. 
GUARANTEE REGISTRATION NUMBER: 723 

 
 
 
 
 
 
 
 

www.varilight.co.uk 

I_I

 

Please record the batch number printed on the 
side of the plastic moulding on the rear of the 
product. This will assist us in providing any 
technical support you may require. 

Reg. 723 

BATCH NO: 

INSTALLERS – Please leave these instructions with your 
customer for future reference. 

WARNING:  Do  not  apply  products  with  metal  faceplates 
directly  to  freshly  plastered  or  damp  surfaces  as  product 
may  tarnish.  If  in  doubt,  use  polythene  as  a  temporary 
gasket to protect the product. Do not use masking tape on 
metal faceplates.  

Reviews: