Installation
1-3
1-3
PHYSICAL SPECIFICATIONS (See Figure 1-2)
Flange dimensions (inches):
ASA
Inlet
Foreline
Inlet
Foreline
35"ASA
6"ASA
ISO-1000-F
ISO-200-K*
OD
41.75
11
44.09
9.45
ID
35 7.72
35.00
7.72
Thickness
1.12
0.75
1.12
0.47
Bolt Circle
38.5
9.5
42.913
–
No. of Holes
28
8
32
–
Size of Holes
0.87
0.81
0.550
–
Orientation
Straddle center line
Gasket Groove
ID
35.37
8.20
40.75
–
wide
0.56
0.17
0.56
–
deep
0.25
0.09
0.25
–
Height
72.13 inches; allow additional 8 inches (min) for
heater removal
Jet Assembly
5-stage, Self-aligning, fractionating design with four
diffusion stages and one ejector stage
Foreline Baffle
Stacked disk and ring
Cold Cap
Water-cooled
Water Connections
3
⁄
8
FPT for pump body and quick-cool coils
Thermal Switches
Upper set at 200°F (92°C)
Lower set at 600°F (315°C)
Materials
Body
Mild steel
Flanges
Mild steel
Jet Assembly
Stainless Steel
Foreline Baffle
Mild Steel
Weight
1220 pounds (pump)
250 pounds (jet assembly)
Shipping Weight
1550 pounds (705 kg)
* Requires NW-200 centering ring (not included with pump)
Summary of Contents for NHS-35
Page 2: ......
Page 4: ......
Page 6: ......
Page 16: ...x...
Page 18: ......
Page 20: ......
Page 22: ...Installation 1 2 Figure 1 1 Speed and Throughput Curves NHS 35 Diffusion Pump...
Page 26: ...Installation 1 6 Figure 1 3 Section Drawing NHS 35 Diffusion Pump...
Page 30: ...Installation 1 10 Figure 1 5 240 400 440V Wiring Diagram NHS 35 Diffusion Pump...
Page 31: ...Installation 1 11 Figure 1 6 380 415V Wiring Diagram NHS 35 Diffusion Pump...
Page 32: ...Installation 1 12 Figure 1 7 480V Wiring Diagram NHS 35 Diffusion Pump...
Page 36: ...Installation 1 16...
Page 48: ......